60P ultra-low temperature water chiller consumes too much energy and needs attention
60p ultra-low temperature water chillers of different manufacturers have different performance configurations and different energy consumption. If you find that the energy consumption is too large, you must check in time to see if there is a problem in any aspect.

1. When there is a fault:
If the 60p ultra-low temperature water chiller equipment is faulty and the cooling performance is continuously reduced, the enterprise must be more cautious when using it. When operating the equipment, if the enterprise ignores the existence of various common faults, although the equipment can be used normally for the time being, the operation safety of the equipment will be directly and seriously affected.
2. When running for a long time:
If the operating time of the 60p ultra-low temperature water chiller equipment is relatively long, and in the process of operation, the company does not provide sufficient rest time for the equipment. Therefore, the security of enterprise use will also be threatened. Wuxi Guanya Constant Temperature Refrigeration Technology Co., Ltd. LNEYA recommends that enterprises can rationally formulate a plan for the operating time of 60p ultra-low temperature water chillers, or use multiple installations for alternate operation.
3. Environmental factors:
When companies use 60p ultra-low temperature water chillers, if there are many inappropriate factors in the environment, the same will happen that energy consumption continues to increase. Therefore, to choose a place with a better environmental location and a workshop with a large enough space, the equipment needs to be installed at the corners or in the middle. Only in this way can the correct location be selected to help the company complete the task efficiently.
Summarize
The above problems may cause excessive energy consumption of the 60p ultra-low temperature water chiller. When users encounter the above problems during use, they can contact the relevant after-sales technicians to solve them in time.
Recomendaciones relacionadas
-
Fault Hint of Cryogenic Chiller Refrigeration System
910When the high and low pressure of the system are higher than normal, there is usually air or excessive refrigerant in the system. At this time, we need to re-vacuum, and then add a proper amount of refrigerant to solve this problem. But there are ...
Ver detalles -
How To Solve The Electric Vehicle Motor Test Condensation Is Too High?
1084The condensing pressure of the electric vehicle motor test will increase, the compression function will increase, the cooling capacity will decrease, the cooling coefficient will decrease, and the energy consumption will increase. The reason for t...
Ver detalles -
Descripción de la temperatura del enfriador de glicol
1010For users and friends, it is necessary tohave a deep understanding of glycol chillers before use. It is recommended toknow the temperature in various equipment such as refrigeration system,evaporating temperature, condensing temperature, etc.If...
Ver detalles -
What are the decarboxylation reaction conditions and process temperature control?
1183The decarboxylation of aromatic acids is easier than that of fatty acids. For example, benzoic acid can be decarboxylated by adding a little copper powder as a catalyst in quinoline solution and heating. When a strong electron-withdrawing group ...
Ver detalles