Ventajas del refrigerador de recirculación de baja temperatura
Low temperature cooling recirculating chiller is a kind of refrigeration using compressor, and the circulating pump provides cold source to maintain the temperature range from – 2 5℃ to 30 ℃. The refrigeration recirculating chiller has a space-saving vertical configuration and good heat dissipation effect. It can effectively control the external closed liquid loop when the temperature is far lower than 0 ℃. It is suitable for water, oil or other media of the manufacturer. All recirculating chillers can be connected with other equipment through hoses and used as a constant temperature source.
The high and low pressure of the low-temperature recirculating chillers are 2.5bar and 0.7bar respectively. The air-cooled fully enclosed compressor unit is used for refrigeration, microcomputer intelligent control, automatic opening and delayed closing of the refrigeration system, overheating and current multiple protection devices. It is widely used in petroleum, chemical industry, medicine, life science, metrology, light industry, scientific research and other fields.
Advantages of low temperature cooling recirculating chiller:
1. One of the characteristics of the refrigeration cycle is the large single pressure ratio, but with the increase of the pressure ratio, the efficiency of the screw chiller decreases and the power consumption is large.
2. In order to expand the application range of screw chiller, improve the performance at low temperature and achieve the purpose of energy saving.
3. Taking advantage of the unidirectional operation of suction, compression and exhaust of the screw machine, an intermediate air supplement orifice can be set at a certain position where the rotor starts to compress, so that the single screw refrigerator can operate according to two compression, that is, the screw chiller with economizer.
4. It is usually used when the evaporation temperature is – 25 ℃ ~ 30 ℃. Compared with the original single screw chiller, the refrigeration capacity and refrigeration efficiency are greatly improved, and electric energy can be saved at the same time.
Recomendaciones relacionadas
-
LNEYA hot and cold machine SUNDI manual
2082The temperature range of the hot and cold machine ranges from -120 ° C to 350 ° C. It has superior performance and unique performance. It has high precision and intelligent temperature control. The high cooling power is from 0.5 to 1200 kW. High p...
Ver detalles -
How to Maintain Low Temp Chillers
1490Low temp chiller is a kind of refrigeration mechanical equipment which needs to be used in many industrial production operations. It can provide very good refrigeration technology for different production operations and ensure the smooth progress ...
Ver detalles -
Hybrid car battery test equipment cooling capacity description
1632Due to insufficient insulation thickness of the hybrid vehicle battery test equipment and pipeline or damage to the insulation layer, the loss of cooling capacity is increased, which affects the cooling effect. In the operation of the hybrid vehic...
Ver detalles -
Heat transfer oil secondary circulation system use instructions
1537The thermal oil secondary circulation system is equipped with various instruments and equipment for temperature control. When using it, you need to pay attention to its safety knowledge and safer operation. LNEYA heat transfer oil secondary circul...
Ver detalles
LNEYA Enfriadoras industriales Fabricante Proveedor