Advantages of low temperature cooling recirculating chiller
Low temperature cooling recirculating chiller is a kind of refrigeration using compressor, and the circulating pump provides cold source to maintain the temperature range from – 2 5℃ to 30 ℃. The refrigeration recirculating chiller has a space-saving vertical configuration and good heat dissipation effect. It can effectively control the external closed liquid loop when the temperature is far lower than 0 ℃. It is suitable for water, oil or other media of the manufacturer. All recirculating chillers can be connected with other equipment through hoses and used as a constant temperature source.
The high and low pressure of the low-temperature recirculating chillers are 2.5bar and 0.7bar respectively. The air-cooled fully enclosed compressor unit is used for refrigeration, microcomputer intelligent control, automatic opening and delayed closing of the refrigeration system, overheating and current multiple protection devices. It is widely used in petroleum, chemical industry, medicine, life science, metrology, light industry, scientific research and other fields.
Advantages of low temperature cooling recirculating chiller:
1. One of the characteristics of the refrigeration cycle is the large single pressure ratio, but with the increase of the pressure ratio, the efficiency of the screw chiller decreases and the power consumption is large.
2. In order to expand the application range of screw chiller, improve the performance at low temperature and achieve the purpose of energy saving.
3. Taking advantage of the unidirectional operation of suction, compression and exhaust of the screw machine, an intermediate air supplement orifice can be set at a certain position where the rotor starts to compress, so that the single screw refrigerator can operate according to two compression, that is, the screw chiller with economizer.
4. It is usually used when the evaporation temperature is – 25 ℃ ~ 30 ℃. Compared with the original single screw chiller, the refrigeration capacity and refrigeration efficiency are greatly improved, and electric energy can be saved at the same time.
Recomendaciones relacionadas
-
Fallos comunes y análisis de causas de enfriadoras refrigeradas por aire
1192Durante el uso de equipos de refrigeración por aire, es inevitable encontrar algunos fallos comunes. Los usuarios deben conocer las posibles causas de los fallos y encontrar soluciones a tiempo para que la producción y el funcionamiento sean más estab...
Ver detalles -
Trouble shooting method for refrigeration device of air-cooled chiller chemical reaction kettle
940If air enters into the air-cooled chiller refrigeration unit system of the chemical reaction kettle, the impact will be many. Enter the air circulation system first, the pressure will rise, the heat dissipation effect of the condenser will also be...
Ver detalles -
What is the reason why the industrial chiller system cannot be cooled
1240Let the LNEYA technical engineer explainthe reason for everyone: The first one: The chiller system fails tolower the temperature during the first use, or there is a problem with theinstallation of the industrial water chiller, cooling tower, ...
Ver detalles -
Heating and cooling system for chemical reaction kettle reaction process
1157In the process of chemical chemical reaction, material temperature is an important production process parameter. For example, in salt crystallization, solution separation, organic pigment and intermediate processing, temperature control is particu...
Ver detalles