Practical application area of air-cooled chiller
Air cooled chillers, as the name implies,
are mainly used in colleges and universities, scientific research and
laboratories. Specially for the cooling of small laboratory equipment such as
spectrometer, mass spectrometer, viscometer, rotation, fermentation device, a
rotary evaporation apparatus, etc. to make them work under the suitable working
temperature.
In fact, the lab water chillers are also
called air cooled chillers. It can also be used for cooling with small
instruments or small power equipment. For example:
1. Vacuum pump and medical equipment:
molecular pump, diffusion pump, cooling blanket, X-ray machine, nuclear
magnetic resonance, accelerator;
2. Industrial equipment and other: laser
equipment, vacuum coating equipment, biological pharmacy, mold, machine tool,
vacuum furnace, welding machine, reaction kettle.
3. Matched small vacuum pumps, such as
molecular pumps, oil and gas recovery pumps, small roots pumps, rotary disc
pumps, slide valve pumps, etc. It has the advantages of convenient connection,
simple operation, stable temperature, and saving water and electricity,
providing a stable temperature environment for the vacuum equipment, and
providing the operating efficiency of the equipment.
Air cooled chillers belong to LNEYA refrigeration
heating system temperature control equipment.
Advantages and functions of temperature
control system of refrigeration:Temperature range from 120℃ a 350℃,
performance superior, unique, high – precision, intelligent temperature
control.High cooling power from 0.5 to 1200kW, highest production stability and
repeatable results.Multi-function alarm system and safety function, use plate
heat exchanger, tube type heater to increase heating and cooling rate.
No heat conduction medium evaporates at high
temperature, and it can be achieved -80℃~190℃, -70℃~220℃, -88℃~170℃, -55℃~ 250℃, -30℃~ 300℃ continuous
temperature control without pressurization.The principle and the function has
many advantages to using staff: because only expansion of cavity in the body
heat conduction medium contact with oxygen in the air (and expansion tank
temperature at room temperature to 60℃), can achieve lower
heat conduction medium absorbed by oxidation and the risk of air moisture.
Recomendaciones relacionadas
-
Instrucciones de fugas internas del frigorífico de temperatura ultrabaja a prueba de explosiones
18691. Sound leak detection method: First, the refrigeration pipeline of the explosion-proof ultra-low temperature refrigerator is filled with nitrogen. Then use a stethoscope to check the interior. When you hear a leak in a certain area, mark it. Car...
Ver detalles -
Fault Hint of Cryogenic Chiller Refrigeration System
1429When the high and low pressure of the system are higher than normal, there is usually air or excessive refrigerant in the system. At this time, we need to re-vacuum, and then add a proper amount of refrigerant to solve this problem. But there are ...
Ver detalles -
¿Qué procesos de las empresas de materiales ultrafinos requieren enfriadores de agua de refrigeración?
1540Las empresas de materiales ultrafinos suelen necesitar un control preciso de la temperatura durante el proceso de producción para garantizar la calidad del producto y la estabilidad del proceso de producción. Los enfriadores de agua desempeñan un papel clave en múltiples procesos de...
Ver detalles -
What aspects need to be considered in the external circulation cooling system of the test bench?
1655As we all know, the test room needs to be equipped with a cooling system for vehicle performance and comprehensive transmission, road simulation, electromagnetic compatibility, power battery, vehicle environment and other tests. In the automobile...
Ver detalles
LNEYA Enfriadoras industriales Fabricante Proveedor