What is the reason why the industrial chiller system cannot be cooled
Let the LNEYA technical engineer explain
the reason for everyone:
The first one: The chiller system fails to
lower the temperature during the first use, or there is a problem with the
installation of the industrial water chiller, cooling tower, circulating water
pump and piping. Need to check carefully according to the installation drawing.
The second one: It may be because the
pipeline is connected to various equipment for a long time, and impurities
accumulate in the water source, which causes the water flow to become smaller.
Therefore, we must clean the pipes between the equipment.
Third: If this problem occurs during the
first use, it may be caused by a mismatch of the chiller and a shipping
problem. Because the industrial water chiller has undergone 100% performance
testing before leaving the factory to ensure the normal operation of the unit.
Finally, if it is a chiller that has been
used for half a year or 1-2 years, it may be caused by a leak of Freon in the
cooling system of the chiller. It is recommended to find out the leaks,
re-soldering, and re-soldering the refrigerant. The heat exchanger of the
industrial water chiller is dirty and needs to be cleaned. Remember to clean it
regularly in the future.
The operation of any industrial water chiller
system is inseparable from the participation of refrigerants. Therefore, the
shortage of refrigerant will also affect the normal operation of industrial
chillers, leading to reduced cooling capacity or even shutdown
of industrial water chillers. This is also the main reason for the shrinking
capacity of industrial chillers.
Recomendaciones relacionadas
-
what are the causes of the blockage of the cooler
949The cooler is a very important part of the screw air compressor. The main function is to cool the lubricating oil of air compressor and the compressed air. If it's blocked, then the temperature will go up. A main cause of the air compressor failur...
Ver detalles -
Selection of ultra-low temperature chiller supporting the glass reactor
996In order to achieve an economical ultra-low temperature environment for glass reactors, many customers will not choose multi-stage compressor refrigeration equipment with more than two stages, but use liquid nitrogen. The cost of liquid nitrogen...
Ver detalles -
Características y aplicaciones de las enfriadoras de glicol
1119El enfriador de glicol se aplica al proceso de enfriamiento de máquinas rectificadoras, máquinas herramienta CNC y varias máquinas herramienta de precisión, que pueden reducir eficazmente la deformación térmica de las máquinas herramienta, mejorar la precisión de mecanizado de las máquinas herramienta y...
Ver detalles -
High temperature test equipment related troubleshooting
1066The high temperature test equipment is mostly caused by water shortage in the water circulation. This way, the purified water is replenished to the water tank until the water level meter on the lower right side of the water tank reaches about 80% ...
Ver detalles