¿Cómo resolver el problema del bajo rendimiento de refrigeración del sistema de circulación de aceite térmico?
Some heat-conducting oil circulation systems will not be as good as before after 3 months of use. At this time, it is recommended to contact the professional after-sales department to check the user’s power supply and whether the equipment is normal. The test heat conduction oil circulation system is set to cool operation, and the working pressure is 4.5kg/cm2. Considering that the variable frequency heat transfer oil circulation system uses the electronic expansion valve to throttle, it is not accurate to judge the fault only by the working pressure. Therefore, the outdoor working current is measured again. The measurement finds that the working current is only 10.5A, which is much smaller than the rated value, and the fault is determined as “ Lack of refrigerant.”
Then, first find out the refrigerant leakage part of the heat transfer oil circulation system. Try to open the mechanism heat, use the washing spirit liquid to coat the joints for leak detection, and find that the joint is not tightened, which is the cause of refrigerant leakage. After tightening, check the leak again to make sure the pipeline is intact and then charge the system with refrigerant.
The heat transfer oil circulation system uses the “constant flow charging method”. In order to ensure the accuracy of the refrigerant charge, the exhaust pipe temperature sensor is first suspended. After starting up, use the ammeter to measure the current on the outdoor power line of the heat transfer oil circulation system. As the refrigerant replenishment increases, the current will gradually increase. When the rated current value reaches 12A (the 70-type inverter cabinet is 16A), the refrigeration The dosage of the agent is appropriate. This method is often used during home repairs.
If the heat transfer oil circulation system is overhauled or the leak is too large, and the refrigerant has leaked out in the system for a long time, the refrigerant can be charged by the quantitative method. First, the system is evacuated, and vacuuming or external air evacuation can be used. Then, the system is filled with refrigerant according to the standard. If the external air is emptied, it should be slightly less than the standard amount and in the cold state. These are the reasons why after a few months of use, suddenly become uncooled or poorly cooled.
LNEYA provides professional heat transfer oil circulation system, which is mainly engaged in professional brand equipment, with safe and reliable quality. If you need it, please come and purchase it.
Recomendaciones relacionadas
-
¿A qué debo prestar atención al colocar circuladores de bucle cerrado de alta y baja temperatura?
1472Existen ciertas diferencias en el tamaño y el rendimiento de los termostatos cerrados de alta y baja temperatura de distintos fabricantes. Los usuarios deben prestar atención a la posición de colocación cuando los coloquen después de comprarlos. Si la colocación...
Ver detalles -
What aspects need to be considered in the external circulation cooling system of the test bench?
1652As we all know, the test room needs to be equipped with a cooling system for vehicle performance and comprehensive transmission, road simulation, electromagnetic compatibility, power battery, vehicle environment and other tests. In the automobile...
Ver detalles -
Ultra Low Temp Chiller Compressor Common Protection Instructions
1436The ultra low temp chiller compressor is a relatively important part of all its components. In the course of operation, certain protective devices are needed to help the compressor operate safely. What specific protection? Let's take a look! The m...
Ver detalles -
The maintenance and maintenance of an ultra-low temperature refrigerator
1947The maintenance and maintenance of an ultra-low temperature refrigerator are very important for normal usage and prolonging its life. If the inaccurate temperature control often results in the damage of the protected objects, which will greatly af...
Ver detalles