How to choose the pipeline for condensing adsorption recovery vocs?
Condensate adsorption recovery vocs device at the time of selection, its system configuration needs to be clear to be able to buy with confidence, then, the condensation adsorption recovery vocs pipeline attention points, how to choose?
Condensate adsorption recovery vocs should be as short as possible in the pipeline connection with the controlled substance, reduce bending, when the pressure of the circulation pipeline is too large, the pipeline pressure is insufficient, it will cause the pipeline, the reactor to crack, high temperature, The possibility of spraying low-temperature heat-conducting medium may cause injury, burns, frostbite and ignition of flammable materials, pollution caused by loss of reactants, property damage, and even poisoning of personnel.
The pipeline connection should be sealed and firm, and it has measures such as anti-vibration, grounding, rust prevention and pressure keeping. It can effectively prevent the pipeline from vibrating and corroding, causing cracks and leakage, and there is a danger of static electricity.
Condensate adsorption recovery vocs When connecting with controlled equipment, pay attention to the link of the pipeline, do not have the interface error, generally the liquid outlet corresponds to the inlet, the inlet is connected to the outlet, if it is water-cooled, The water outlet corresponds to the water return port, the water inlet corresponds to the water outlet, and the liquid discharge port (used when the heat medium is replaced) corresponds to the waste liquid collection and collection port.
In the selection of the pipeline, if the use of improper / damaged hoses and / or hose joints, it will lead to personnel injury, it is recommended that the metal insulation hose temperature range -60 ~ 250 ° C; pressure ≤ 2.5 bar.
Condensate adsorption recovery vocs When you carefully configure the metal insulation hose and other pipelines, please refer to their pressure and overpressure capabilities, caliber, and temperature range. At this time, it is necessary to consider the head pressure of the circulating pump inside the equipment. It is recommended that the condensing adsorption recovery vocs should select a pipeline of good quality and sufficient volume such as seamless steel pipe.

When selecting insulation materials, the temperature range of condensing adsorption recovery vocs should be considered first. It is necessary to select the flame retardant material. The temperature range of the insulation material should include the temperature range of the equipment, and there is a margin greater than 30 °C. When the user ignores this problem, There is a possibility of fire. There is also a sufficient amount of insulation material package for condensing adsorption recovery vocs, otherwise the equipment control will not achieve the expected results.
Each component of the condensing adsorption recovery vocs device is very important for its performance. Therefore, it is recommended that the user select the specific parameter configuration and then make a decision when selecting the condensing adsorption recovery vocs.
Recomendaciones relacionadas
-
Chemical cooling and heating system – dynamic temperature control system manufacturer
834In the pharmaceutical and chemical industries, cooling and heating system are widely used. As the developing of internet, many enterprises compete fiercely. The following will introduce the benefits of the LNEYA chemical cooling and heating system...
Ver detalles -
Way to Check Problems of the Lubricating Oil System of the Screw Chiller Factory
966Everyone pays more attention to the refrigerant circulation system and the chilled water circulation system of the screw chiller factory operation system. However, lubricating system is often neglected by everyone. In fact, this system of cold wat...
Ver detalles -
¿Cuál es la temperatura del circulador de refrigeración criogénica?
1007The LNEYA cryogenic cooling circulator has a cooling temperature range from -125 degrees to -20 degrees. It adopts a computer cascade temperature controller and a PT100 temperature sensor, and the temperature control accuracy can reach ±0.1 degree...
Ver detalles -
Analysis of the environmental requirements of the -20 °C freezer
1049Due to the difference in ambient temperature, there are certain requirements for the freezer. Today LNEYA came to tell you how the ambient temperature is good for the -20 °C freezer. Now there are many types of freezer boxes: hot and cold temperat...
Ver detalles