What should you pay attention to when using the cooling and heating oil bath?
In the high and low temperature control, cooling and heating oil bath is one of the more important equipment. What aspects do users need to pay attention to when running the device?
En cooling and heating oil bath equipment should be kept clean and dry. It is strictly forbidden to heat the solution in the stainless steel pot without burning the heater to avoid burning the heater. If the measured temperature differs greatly from the actual temperature, it is usually obtained with the wrong sensor. Place the sensor in boiling water and the meter should display 100 °C. Otherwise check that the sensor is consistent with the meter input type.
En cooling and heating oil bath meter indicates that the HHH is the measured value that is outside the meter range or the thermocouple is broken. It indicates that the LLL is the measured value lower than the lower limit of the meter range or the thermocouple is reversed. The instrument of the cooling and heating oil bath shows normal, the temperature suddenly loses control, and the external load should be checked for short circuit or open circuit.

When the cooling and heating oil bath is not working, the power should be cut off. To ensure safety, please connect the ground wire during use. The electric power and the heat taken away from the load by the refrigerant need to be removed from the radiator at the front hood. The front hood is filled with dust and cotton wool, which will prevent the heat from being dissipated and the cooling effect will be greatly reduced. Generally, the decrease in cooling capacity under normal use conditions is caused by poor ventilation or high ambient temperature.
When the cooling and heating oil bath is in operation, it is necessary to understand these points of use and then operate better.
Recomendaciones relacionadas
-
Introduction and advantages of cryogenic refrigeration system
1172The medium-sized single-fluid cryogenic refrigerator produced by our company has a cooling temperature range from -150℃ to -5℃, fast cooling speed, safe and reliable, used for rapid liquid cooling, applied to high-tech such as biochemical, freeze-...
Ver detalles -
Description of the principle and mode of industrial water chiller refrigeration cycle
1269Anyone who knows about industrial waterchillers should know that it uses compressors to achieve the cooling effect.So, how does it work when refrigerating?1. Vapor compression refrigeration cycle.After cooling and pressurizing the vaporfrom the...
Ver detalles -
Manufacturer explains what are the influences of the oil level and oil difference of the chiller?
1149The chiller manufacturer tells everyone that in addition to the refrigeration system, the lubricating oil system is also an important part, with its own oil reservoir and special oil cooler. Therefore, we must understand the influence of the oil l...
Ver detalles -
Application of refrigeration and heating temperature control system in chemical synthesis
874chemical synthesis cooling heating system temperature control unit
Ver detalles