Enfriador de agua para pruebas de alta y baja temperatura de combustible de aviación
High and low temperature cooling of aviation fuel usually requires the use of water-cooled chillers rather than air-cooled chillers. This is because water-cooled chillers have higher energy efficiency and better temperature control accuracy, and are more suitable for the cooling needs of aviation fuel.
Application of water chillers in high and low temperature testing of aviation fuel:
Low temperature requirements:
- Fuel freezing point test: used to test the freezing point of aviation fuel at low temperatures to ensure that the fuel will not freeze under cold conditions.
- Low temperature performance test: evaluate the performance parameters such as fluidity and viscosity of aviation fuel under low temperature conditions to ensure that the fuel can be transported and burned normally at low temperatures. In cold areas, the fuel may need to be cooled between -40°C and -50°C.
High temperature requirements:
- Thermal stability test: evaluate the thermal stability of aviation fuel under high temperature conditions to ensure that the fuel will not decompose or produce harmful substances under high temperature conditions.
- Volatility test: test the volatility of the fuel at high temperatures to ensure that the fuel will not volatilize excessively under high temperature conditions. In high temperature areas, the fuel may need to be cooled between 30°C and 40°C.
Temperature Cycle Test:
•Thermal Cycle Performance Test: Simulates the cyclic changes of aviation fuel under different temperature conditions to evaluate the performance stability of the fuel under temperature change conditions. It is usually necessary to control the temperature within the range of ±1°C to ±0.5°C to ensure the stability and safety of the fuel during transportation and storage.
Temperature Variation Range:
•Aviation fuel may experience large temperature changes in different seasons and regions, so the cooling system needs to be able to adapt to a wide temperature variation range. The water chiller needs to be able to operate over a wide temperature range, usually covering a range from extremely low temperatures (such as -60°C) to higher temperatures (such as above 40°C). The ability to quickly switch between high and low temperatures to simulate the rapid temperature changes of aviation fuel under different temperature conditions is very important for evaluating the thermal cycle performance of the fuel.
In summary, water-cooled chillers are more suitable for the high and low temperature cooling needs of aviation fuel due to their high energy efficiency, precise temperature control and stability. When selecting a chiller, it is also necessary to consider factors such as specific application scenarios, cooling requirements, available space, and ease of maintenance.
LN -60°C~ -10°C
适用范围 Características del producto 产品参数 Parámetros del producto 行业应用 APLICACIÓN 航空航天材料|试验装置控温解决方案 在航空航天领域,材料的性能直接关系到飞行器的安全、可靠性和...
LJ -45°C~ -10°C
Refrigeración rápida y baja temperatura de refrigeración -5~-150°C Refrigeración por agua LNEYA se especializa en la producción de refrigeradores criogénicos de un solo fluido. La temperatura de refrigeración oscila entre -150°C y -5°C, lo que puede me...
LD -80°C~ -30°C
1.Temperatura oscila entre -5℃ ~ -150℃, puede satisfacer diferentes temperaturas2. Compresor de pistón semi-cerrado de marca famosa, compresor de pistón bipolar semi-cerrado, compresor de tornillo semi-hermético, marca principal son BOCK. Bitzer,...
SLJ -110℃~-150℃
1.Temperatura oscila entre -5℃ ~ -150℃, puede satisfacer diferentes temperaturas2. Compresor de pistón semi-cerrado de marca famosa, compresor de pistón bipolar semi-cerrado, compresor de tornillo semi-hermético, marca principal son BOCK. Bitzer,...
CDLJ -110°C~ -50°C
Enfriador de 5kW; Enfriador de 10kW; Enfriador de 30kW; Enfriador de 60kW; Enfriador de 120kW Ampliamente utilizado en las industrias química, farmacéutica, bioquímica y otras en el campo de la reacción a baja temperatura, velocidad de refrigeración, seguridad y fiabilidad....
cargando...
已经是到最后一篇内容了!
Recomendaciones relacionadas
-
LTG Screw Chiller Units
2234It is suitable for various production process cold sources in chemical, pharmaceutical, machinery and other fields, and can provide -110℃~30℃ refrigeration medium, which can be used as ice storage, low temperature air supply and ot...
Ver detalles -
Hash water quality analyzer chiller
803Hash water quality analyzer often requires precise temperature control when performing water quality analysis to ensure the accuracy and reliability of the measurement results. Chillers are one of the important devices that provide thi...
Ver detalles -
How to Select Air Cooled Chiller and Water Cooled Chiller?
591LNEYA offers you free guidance on choosing the right chiller, along with a wide range of air-cooled and water-cooled chillers with different performance options.
Ver detalles -
The role of chiller in the manufacturing process of catalytic materials
953In the field of new material preparation, by accurately controlling the reaction temperature, the influence of different temperatures on the microstructure and macroscopic properties of materials can be explored, thereby developing new mat...
Ver detalles