What should I pay attention to when choosing an evaporator for an ultra-low temperature chiller?
The evaporator in the ultra-low temperature chiller is one of its four major components, so performance is more important.
The selection of ultra-low temperature chillers needs to pay attention to the influence of liquid level on the evaporation temperature. Due to the influence of the height of the refrigerant liquid column, the evaporation temperature at the bottom of the flooded evaporator is higher than the evaporation temperature of the liquid surface. The evaporation temperature of different refrigerants at different liquid levels is affected differently by the height of the static liquid. Regardless of the refrigerant, the lower the evaporation temperature of the liquid surface, the greater the influence of the hydrostatic height on the evaporation temperature. Therefore, only when the evaporation pressure is high, the influence of the hydrostatic height on the evaporation temperature can be ignored. When the evaporation temperature is low, it cannot be ignored. In other words, it becomes uneconomical to use a flooded evaporator at this time.
If the evaporation temperature is lower than the freezing temperature of the refrigerant, the refrigerant may freeze. In the subsequent flow of the refrigerant, the temperature of the refrigerant is low, and the possibility of freezing is high. When water is used as the refrigerant, theoretically, the temperature of the inner wall of the tube can be as low as 0°C. However, for safety reasons, the temperature of the inner wall of the pipe at the outlet end of the next process is usually kept above 0.5°C. In the case of brine as the refrigerant, according to the same principle, the temperature of the inner wall of the tube should be higher than the freezing temperature of the refrigerant by more than 1°C.
When the refrigerant flows through the evaporator, pressure loss is caused, which will inevitably make the pressure p2 of the refrigerant at the outlet of the evaporator be lower than the pressure p1 at the inlet, thereby reducing the suction pressure of the compressor, resulting in a decline in the refrigeration capacity.
According to different models, the choice of evaporator is different. For example, the box-type small ultra-low temperature chiller uses a water tank coil type evaporator; the open-type small ultra-low temperature chiller and the screw-type small ultra-low temperature chiller use shell and tube Type evaporator; for acid and alkali resistant ultra-low temperature chillers, you can choose titanium tube evaporator or stainless steel plate exchanger; there are many options, of course, it can be customized according to user needs.
The ultra-low temperature chiller evaporator is generally designed and equipped by the ultra-low temperature freezing test manufacturer. It is recommended that users check the configuration problems when choosing the ultra-low temperature chiller manufacturer.
Recomendaciones relacionadas
-
¿Qué tipo de cámara de pruebas para baterías se encuentra en el laboratorio?
1268La aplicación de la cámara de pruebas de baterías en el laboratorio debe cumplir una serie de requisitos estrictos para garantizar la precisión y seguridad de los resultados de las pruebas. Estos requisitos se refieren principalmente a los siguientes aspectos:
Ver detalles -
Sistema de control de la temperatura de refrigeración y calefacción del sistema hidráulico
1251La aplicación del sistema de control de temperatura de refrigeración y calefacción en el sistema hidráulico es muy crítica, especialmente en ocasiones en las que se requiere un control preciso de la temperatura. Este sistema puede garantizar que el aceite hidráulico se mantenga dentro de los...
Ver detalles -
¿Cómo conectar a tierra el conductor de prueba de la batería del vehículo eléctrico?
1648La prueba de la batería del vehículo eléctrico está en el estado de funcionamiento, y es necesario entender el funcionamiento de los accesorios, y la unidad y otros accesorios están en funcionamiento. Si la prueba de la batería del vehículo eléctrico no está aislado entre la A...
Ver detalles -
Las principales áreas de aplicación de las enfriadoras por aire
1894En el mercado nacional e internacional de enfriadores de agua industriales, nuestros equipos más comunes de enfriadores de agua industriales pueden dividirse a grandes rasgos en dos tipos diferentes, un tipo es el enfriador de aire industrial, el otro tipo es el enfriador de agua industrial....
Ver detalles