Effect of evaporator on refrigeration system in special instrument for low temperature experiment
The low temperature experiment special instrument is LNEYA’s refrigeration heating equipment for the laboratory. The importance of the evaporator is self-evident. So what effect does the evaporator have on the refrigeration system?
According to different models, the choice of evaporators for low-temperature experiment special instruments is also different, such as box-type low temperature experiment special instruments, using water tank coil evaporator; open low temperature experiment special instrument and screw type refrigerator, then choose Shell and tube evaporator; for special instruments for acid and alkali resistance low temperature experiments, titanium tube evaporator or stainless steel plate exchanger can be selected. An ice water machine can have a variety of options, of course, can be customized according to user needs.
The temperature condition of the evaporator of the low-temperature experiment special instrument: under normal circumstances, the outer surface of the evaporator is very cold, and the condensation water droplets are continuously dripped, and the temperature of the inlet and outlet air is relatively large, usually Δt can be 12~14 ° C. The surface of the evaporator is not too cool, there is not much dew, or condensation, and the sound of the refrigerant flow is very loud, and the temperature difference between the inlet and outlet is small. The reason is that the refrigerant amount is insufficient, or the expansion valve opening degree is small.
The factors affecting the evaporation temperature of special instruments for low temperature experiments are as follows:
Evaporator pipe oiling: Under normal circumstances, due to the mutual solubility of lubricating oil and refrigerant, oil film will not form on the surface of the heat exchanger, and the thermal resistance of the oil film may be disregarded. However, in the case of additional lubricating oil, it must be the same as the original one. Lubricating oil to prevent the formation of oil film. Air filter plugging: The filter must be replaced regularly to ensure the required air circulation for the air conditioner. Dry filter plugging: In order to ensure the normal circulation of the cooling enthalpy, the refrigeration system must be kept clean and dry. If the system has impurities, the drying filter will be blocked, the system will be difficult to supply liquid, and the cooling effect will be affected. Too little refrigerant, additional refrigerant.
The evaporator of the low-temperature experiment special instrument also has certain requirements in terms of quality. The brand has a certain quality guarantee, so that the operation will be more stable.
Recomendaciones relacionadas
-
About the size and installation height of refrigeration heating temperature control system equipment
1393Whether it is biopharmaceutical, traditional Chinese medicine or chemical pharmacy, pharmaceutical companies are all related to chemistry, because the extraction and synthesis of pharmaceutical ingredients are all in the form of chemical products...
Ver detalles -
Cooling method for semiconductor testing chiller to meet temperature control requirements
2072The biopharmaceutical field requires high-precision temperature to control the activity of enzymes and the production of products; the chemical industry field requires specific temperatures to stabilize chemical reactions; the electronic manufact...
Ver detalles -
Reunirse en Shanghai World Expo Pavilion 【Pesticide Exhibition】Booth 1G10 10.12-10.14
1998Nombre de la exposición: La 20ª Conferencia Nacional de Intercambio de Plaguicidas y Salón de Exposición de Productos AgroquímicosHora de la exposición: 12-14 de octubre de 2020Número de stand: 1G10Dirección de la exposición: Shanghai World Expo Exhibition Hall ,
Ver detalles -
Precauciones para la refrigeración y el calentamiento durante el funcionamiento de diversos reactores
1543En muchos laboratorios, diversos recipientes de reacción de empresas químicas son recipientes de reacción indispensables, y su temperatura de funcionamiento: -80°C-250°C. El reactor de laboratorio funciona a temperatura normal, y el agua de refrigeración debe pasar normalmente a un...
Ver detalles
LNEYA Enfriadoras industriales Fabricante Proveedor