Maintenance of Glycol Cooling Heating Control System
Apart from the attention needed during the daily use, the regular check and maintenance of Glycol Cooling Heating Control System are also very important. In order to help all of you learn to use Glycol cooling heating more efficiently, Guanya Refrigeration sort out related maintenance, so that you can use it in time.
Screw Compressor
Screw compressor is a very important part of ethylene glycol refrigerator, and the compressor is directly related to the stability of the unit. If the compressor has something wrong, In view of the high precision of the assembly precision of the screw compressor, the factory is usually required to carry out the maintenance, so it needs to be paid more attention in the ordinary use process in using.
Condensers and Evaporators
Is there is something wrong with the Glycol cooling heating control system, in view of the high precision of the assembly precision of the screw compressor, the factory is usually required to carry out the maintenance, so the compressor needs to be paid more attention in the ordinary use process.
Washing of condensers and evaporators
The cooling water of the water-cooled condenser of glycol refrigeration unit is open loop circuit. The circulating water is usually used by the cooling tower. When calcium the content of salt and magnesium salt in water is large, it is easy to decompose the fouling between the pipe and rock, and the heat transfers. Once the scale of the condenser of glycol cooling system is too thick, the cross section of the cooling water will decrease, the water volume will decrease and the condensing pressure will increase. Therefore, when the water quality of the cooling water is poor, the cooling water pipe should be washed at least once a year to remove scale and other contaminants. Of course, not only glycol cooling system but other other related cooling equipment used for a period of time, their maintenance knowledge is needed to learn in everyday use.
Recomendaciones relacionadas
-
What aspects should be paid attention to when using laboratory cryogenic refrigeration circulators?
1543The compact circulating cooler is an economic model for routine laboratory applications. The instrument is cooled in the temperature range of -10 or 0°C to +40°C, and the temperature control accuracy can reach ±0.5°C. It is a good way to replace e...
Ver detalles -
How To Choose the Ultra Low Temperature Recirculating Chiller Expansion Valve?
1615Selection and installation of the expansion valve for ultra low temperature recirculating chillers: the selection of expansion valve plays an important role in the performance of the ultra low temperature recirculating chiller refrigeration system...
Ver detalles -
Instalación y mantenimiento de enfriadoras de agua industriales
1480As a industrial temperature control device,industrial water chiller is often in 24-hour operation. Therefore, it is veryimportant to choose a industrial chiller with good performance. Wuxi GuanyaRefrigeration Technology Co., Ltd. specializes in...
Ver detalles -
The importance of temperature control equipment TCU in the pharmaceutical industry
15181.Low temperature conditions required for biochemical reactions inside the reactor: low-temperature drug synthesis, etc 2.Rapid cooling of raw materials to prevent drug spoilage, low-temperature crystallization and extraction. G...