12hp congelador transferencia de calor instrucciones de selección de aceite
When choosing a 12hp freezer, users need to pay attention to the choice of heat transfer oil. For LNEYA, suitable heat transfer oil is very important. What should you pay attention to when choosing heat transfer oil?
The 12hp freezer adopts a fully enclosed circulation line. Only the heat transfer medium participates in the cycle. The temperature of the expansion tank is always maintained at 60 °C at normal temperature, which avoids the problems caused by air entering the circulation system. The selection and detection of the heat transfer oil of the 12hp freezer is generally carried out from the following four aspects. The viscosity change generally indicates the degree of contamination, thermal cracking and oxidative degradation of the heat transfer oil in the system. When the change is greater than 15%, it should be taken seriously. The flash point change indicates that there is low boiling in the system, and when the change is greater than 20%, attention should be paid. The change in acid value indicates that the heat transfer oil in the system is contaminated or oxidized. When the acid value reaches 0.5, attention should be paid. The increase in residual carbon value generally indicates that it is caused by sputum, corrosives, severe oxidation or severe thermal cracking, and should be taken seriously when it reaches 1.0 (m%).
After the test results are out, if the indicators are out of the range, the heat transfer oil is running well; if one or more of them are out of range, you should consider taking measures to replace the heat transfer oil to restore the heat transfer oil to a good condition. 12hp freezer has more heat transfer oil models, 12hp freezer should choose the right manufacturer’s heat transfer oil.
Wuxi Guanya (LNEYA) recommends using the heat transfer oil of the relevant equipment manufacturer as well, and the miscellaneous brand of heat transfer oil may cause the 12hp freezer to operate poorly.
Recomendaciones relacionadas
-
Benefits of Winterizing and Degassing Prior to Distillation
1536Prior to distilling oil, you should follow a winterization and degassing procedure. The winterization will remove fats, waxes, and other inactive and unwanted compounds. Degassing will remove any solvents and other inactives with low boiling point...
Ver detalles -
The Phenomenon of Ice Jam in Low Temperature Chiller System
1338The phenomenon of ice jam in low temperature chiller system is mainly due to the excessive water in the refrigeration system. With the continuous circulation of refrigerants, the water in the refrigeration system gradually concentrates at the outl...
Ver detalles -
Start-up work for new energy thermal management
1601In the pipeline selection of new energy thermal management, if the use of improper/damaged hoses and/or hose joints will result in injury, the new energy thermal management is limited by the temperature, caliber, installation method, etc. Tube, me...
Ver detalles -
Minimum 40 degree refrigerator use precautions
1725The temperature of the lower 40 degree refrigerator is indoor temperature: 5-32 °C, relative humidity 80%/22 °C, the distance from the ground > 10cm, the altitude below 2000m, the safe environment guarantees a smoother operation of the lower 40...