Maintenance of vacuum pump for fully enclosed heating and cooling circulator
Each accessory in the fully enclosed heating and cooling circulator constitutes the entire refrigeration heating and temperature control system. The performance of the pump is also very important. How to make the maintenance of the pump?
For the fully enclosed heating and cooling circulator circuit, the electronic circuit and the mechanical rotating part are routinely inspected and repaired. Pay attention to whether the various indicators are damaged or deteriorated, and regular maintenance is required.

Do the vacuum pump working status and the registration of each working time, record the cause of the instrument failure and the troubleshooting method in time to ensure that the vacuum pump works in a better state.
Keep the vacuum pump symmetrically balanced. If the sample tube placed in the pump chamber is unbalanced, it will cause the circulating water vacuum pump to shift. After the shutdown is reset, check if the vacuum pump is normal.
Before use, please pay attention to check the rotor for corrosion points and fine cracks. The rotor that has been corroded or cracked is forbidden to use. If the rotor exceeds the shelf life, it should be checked frequently to ensure personal safety.
The fully enclosed heating and cooling circulator vacuum pump cover door bolts should be checked frequently and kept flexible to prevent forced opening or closing. When an abnormality occurs, it is necessary to repair and replace it in time. Common faults, usually pay attention to observation, and promptly eliminate the solution.
After use, the water in the pump chamber should be dried, and a small amount of neutral grease should be applied to the cone surface of the motor shaft periodically. Remove the rotor from the circulating water vacuum pump for a long time, wipe it clean and place it in a dry place.
LNEYA specializes in the production of fully enclosed heating and cooling circulators, refrigeration and heating circulators, TCU, ultra-low temperature freezer, freezer and other equipment of good quality, laughing and welcoming visitors come to negotiate!
Recomendaciones relacionadas
-
About the components of the reactor chiller refrigeration heating circulator
1245The reactor chiller refrigeration and heating circulator is used to control the heater and cooler, adjust the temperature, and maintain the stable temperature of the material. Through the circulating medium, the temperature of the material can be ...
Ver detalles -
Consejos para ahorrar energía en las empresas que utilizan enfriadoras industriales
985Hoy en día se aboga por el ahorro energético, y el consumo de energía siempre ha sido una preocupación para todos. Todo el mundo sabe que los equipos industriales consumen electricidad. Para muchas empresas de fabricación de materiales químicos, la presió...
Ver detalles -
CIPM China [C-48-2] welcomes new and old customers!
1289The 58th (Fall 2019) National Pharmaceutical Machinery & ChinaInternational Pharmaceutical Machinery Expo will be held at the Chongqing International Expo Center from November 5th to November 7th, 2019. It is recognized by the industry as prof...
Ver detalles -
Hybrid car battery test equipment cooling capacity description
1005Due to insufficient insulation thickness of the hybrid vehicle battery test equipment and pipeline or damage to the insulation layer, the loss of cooling capacity is increased, which affects the cooling effect. In the operation of the hybrid vehic...
Ver detalles