How to avoid incorrect operation of heating and cooling thermostat?
When the user is running the heating and cooling thermostat, the operation needs to follow the instructions, so how to avoid inappropriate operations?
Excellent design of hot and cold thermostat:
The LNEYA heating and cooling thermostat has a multi-functional alarm system and safety functions. It uses plate heat exchangers and pipeline heaters to increase heating and cooling rates. Large touch screen graphics display. The heating and cooling integrated machine uses a magnetic drive pump, so there is no shaft seal leakage problem. , Fully enclosed system, extend the life of the heat transfer liquid, a very wide temperature range, no need to replace the liquid medium.
Wrong operation method of heating and cooling thermostat:
The inlet valve of the condenser on the unit that does not need to be opened is not closed before starting up, causing water channeling. Part of the cooling return water of the heating and cooling thermostat will flow away from the condenser of the unit that is not turned on, reducing the cooling water in the condenser of the running unit. Flow, causing the condensing pressure to rise. The operating current of the host increases. The cooling capacity of the unit drops, and in serious cases, the unit will stop running. It not only wastes electricity, but also reduces the cooling effect, and it is easy to damage the equipment.
Due to the previous misoperation, the condensing pressure of the host and the temperature of the cooling water outlet increased, causing misjudgments to the operator of the integrated machine. It is misunderstood that the amount of cooling water is insufficient and the condenser water inlet valve and the cooling water pump outlet valve are opened, and some also increase the cooling tower fan, which causes the power consumption of the water pump and cooling tower fan to increase. In addition, some users blindly added a cooling water pump. Although adding the cooling water pump can indeed reduce the cooling water temperature and condensing pressure, after all, the electrical energy of a water pump is wasted, so it is a mistake.
The correct operation method of heating and cooling thermostat:
The correct operation method of the heating and cooling thermostat is to close the condenser water inlet valve of the unit that does not need to be operated before starting to prevent water channeling. Turning on the heating and cooling thermostat will run the inlet and outlet valves on the condenser of the unit (generally, the outlet valve is normally open, and the inlet valve is opened and closed as needed, the condenser and evaporator are the same) and the corresponding cooling water pump is turned on. Adjust the inlet and outlet water pressure of the condenser to about 68.6kPa (0.7 kg/cm). If the pointer of the condenser inlet and outlet water pressure gauge swings too much, it indicates that there is air in the cooling water system. The air needs to be exhausted and the pressure gauge indicates normal to continue the next step.
Recomendaciones relacionadas
-
The Analysis Of Ultra Low Freezer’S Price
1852What are the characteristics and functions of ultra low freezer:1. Ultra low freezer can prevent the precision of machine equipment from being influenced by the change of oil temperature in the process of operation. 2. Ultra low freezer can preven...
Ver detalles -
Temperature sensor for ultra-low temperature refrigerator
1771Ultra-low temperature refrigerators are used in refrigeration equipment. They are generally used in refrigeration equipment below -60 ° C. They are used under some special conditions under low temperature conditions. Temperature control is very im...
Ver detalles -
Wuxi Guanya: centrarse en la I+D de equipos de refrigeración y calefacción para contribuir al desarrollo de nuevas energías
2219On October 17, 2018, the three-day API was held in Nanjing International Expo Center. The exhibition was crowded with people. Wuxi Guanya was a frequent visitor to the API. Wuxi Guanya Constant Temperature Refrigeration Technology Co., Ltd. (herei...
Ver detalles -
¿Cuál es la razón de que haya gas no condensable en el condensador de agua de refrigeración a temperatura ultrabaja c
2345Cuando el enfriador de agua de refrigeración a temperatura ultrabaja está en funcionamiento, es necesario prestar atención al estado de los gases generados por el condensador a una determinada temperatura y presión. La existencia de estos gases afecta al funcionamiento del ultra...
Ver detalles
LNEYA Enfriadoras industriales Fabricante Proveedor