¿Cómo solucionar el fallo del compresor tras la venta de congeladores de placas frías?
In the operation of the cryogenic refrigerator refrigeration system, once the compressor fault occurs, it will affect the operation of the cryogenic refrigerator. So what are the faults that affect the compressor? How do clients settle it if the compressor fault occurs after cold plate freezer for sale? Before dealing with the compressor fault, we should understand these clearly, as for how to deal with the compressor fault. After the compressor of the cryogenic refrigerator breaks down and the original damaged cryogenic compressor is removed, it requires to carry out nitrogen pollution treatment on system and then connect the new refrigeration compressor system. Next, in order not to generate an oxide film on the inner wall of the copper tube during welding operation, is recommended to inject nitrogenit, and the time for it should be sufficient.
When replacing the compressor of the cryogenic refrigerator, it needs to pay attention not to use the replaced cryogenic refrigerator compressor as a vacuum pump to empty the air in the pipeline of the external machine, otherwise it will burn down the compressor, all uses vacuum pumps for vacuuming. In addition, when the refrigeration compressor is replaced, add an appropriate amount of frozen oil corresponding to the compressor.
When replacing the compressor of the cryogenic refrigerator, attention should be paid to prevent the excessive amount of frozen oil in the system, otherwise, the heat transfer effect of the system will be reduced, resulting in high pressure of the system and damage to the system as well as the compressor.
After the installation of the compressor of the cryogenic refrigerator, it is necessary to check whether the radiator works normally. If the system pressure exceeds the normal pressure (13-15kg), it will cause the clutch to slip, the bearing, the coil can be burnt out or the compressor can be damaged.
After cold plate freezer for sale, the compressor fault is solved and it is installed, at the same time, check whether other accessories are affected during installation and disassembly, and put into operation after confirmation.
Recomendaciones relacionadas
-
Explicación detallada de la atención a la depuración del sistema de refrigeración de circulación cerrada
1774La preparación del sistema de refrigeración de circulación cerrada antes de la puesta en servicio es una parte importante del proceso de depuración, que puede afectar al progreso de todo el proceso de depuración. En general, se debe prestar atención a la detección de fugas...
Ver detalles -
What should I pay attention to when adding refrigerant to a water-cooled chiller
1771In our life, we believe that everyone isvery familiar with refrigeration. In the central air conditioning andindustrial production process cooling industry, small water-cooled chillers ismore common. This unit is composed of a compressor in the...
Ver detalles -
Basic maintenance of high and low temperature refrigeration circulating pumps
2159Properly perform the sequence of opening and closing of the high and low temperature refrigeration cycle pump group to ensure normal operation after the host is started. Note that the condenser heats up well, otherwise the high temperature protect...
Ver detalles -
Consejos de marca del ultracongelador
1404Cuando se trata de congeladores de temperatura ultra baja, la mayoría de las personas se preocupan porque la temperatura ultra baja significa que la tecnología se vuelve más difícil. En comparación con otras plantas de refrigeración, las opciones de congelador de temperatura ultra baja...
Ver detalles
LNEYA Enfriadoras industriales Fabricante Proveedor