Maintenance Method of Condenser in Water Chiller Units
The condensers used in small water chiller units are divided into air-cooled condenser and water-cooled condenser.
Air-cooled condenser is mainly used in air-cooled water chillers. It uses air as cooling medium. Because there are often dust or other sundries in the air, some of these dust or sundries will fall on the outside surface of the condenser fins. Over the years, the cooling effect of the condenser will become worse, especially in the bad environment. Therefore, we should clean regularly.
The cleaning method of air-cooled water cooler condenser is: pure dust can be washed clean by compressed air or vacuum cleaner. If there are more dirt on the condenser, gasoline or non-corrosive detergent can be used to clean the heat sink and fins to improve the heat dissipation effect.
Water-cooled condenser is mainly used for water-cooled water chillers. For this kind of condenser, the main problem is to remove scale. Its cleaning cycle is generally based on water quality. If the water quality is poor, it should be cleaned at least once a year. If the water quality is good, such as pure water, it can be cleaned once every 2 to 3 years.
Perhaps some of the chillers use cased water condensers, which can be pickled.
The operation method is: unload the condenser, release the accumulated water inside, and then inject 10% dilute sulfuric acid solution into the condenser tube until the outlet has a solution to flow out. The dilute sulfuric acid can be released after 20 to 30 minutes in the condenser. This action is repeated two or three times.Finally, install the connecting pipe between the cooling water pipe and the condenser, open the cooling water valve and wash for 10 to 20 minutes, and the anti-scaling and cleaning work will be finished.
Our company provides small water chiller units, welcome to buy!
Recomendaciones relacionadas
-
Various reactors and materials use PLC temperature control system
1850The PLC temperature control system is used for the lifting and constant temperature control of glass reactors, metal reactors and bioreactors, especially for heat exothermic control in the reaction process. The heat transfer oil in the jacket of t...
Ver detalles -
Why do mechanical factories need chillers?
1286There are many reasons why mechanical factories need chillers, and chillers play a very important role in the mechanical processing process, which can improve production efficiency, ensure stable operation of equipment, and extend equipment ...
Ver detalles -
¿Cómo elegir los equipos de ensayo de envejecimiento a baja y alta temperatura?
1808La capacidad de refrigeración y el rango de temperatura de los materiales de las distintas industrias son diferentes. En general, la capacidad de refrigeración se divide en 80kw, 120kw, 180kw, 240kw, 360kw, y la temperatura de refrigeración oscila entre -25°C y -5°C. ...
Ver detalles -
Instrucciones para el montaje en frío de rodamientos en frigoríficos industriales de temperatura ultrabaja
1536El sistema de refrigeración de los frigoríficos industriales de temperatura ultrabaja adopta generalmente el principio de funcionamiento de la refrigeración en cascada, y se utilizan dos compresores totalmente cerrados como compresores de alta y baja temperatura. El tubo de cobre del...
Ver detalles
LNEYA Enfriadoras industriales Fabricante Proveedor