Precautions For Compressor Installation of the Screw Chiller Factory
When the operating conditions of the screw chiller factory restrict the compressor to be installed in a small enclosed space, its ventilation environment should be considered. It is necessary to add ventilation and exhaust equipment to facilitate circulation of air. The capacity of the ventilation and exhaust equipment must be greater than the exhaust volume of the compressor cooling fan, and the exhaust inlet position should be suitable for the hot exhaust outlet position of the compressor. Precautions for compressor installation of the screw chiller factory:
1. The compressor shall adopt a unit with large bearing capacity, and its operating speed and acceleration shall be limited within the permitted range.
2. Try to install the compressor of the screw chiller factory in a cool, clean and well-ventilated place to ensure that the air around the compressor is clean and the moisture content is minimized.
3. The air sucked by the compressor is not allowed to contain combustible gas and corrosive gas, so as not to cause internal explosion or internal embroidery.
4. Air-cooled machines should preferably have exhaust fans or air ducts to direct hot air out of the room to prevent hot air from circulating to the air inlet.
Commissioning of the new screw chiller factory shall be carried out by commissioning technicians designated or approved by the manufacturer. The compressor cannot work under the exhaust pressure higher than that specified on the nameplate, otherwise the motor will be overloaded and burnt out.
Cuando el screw chiller factory is running, strictly check the running direction of the compressor. When reverse rotation is found, stop the machine immediately, cut off the power supply, switch any two of the three-phase lines, and restart the machine. Otherwise, the compressor of the screw chiller factory will be damaged (attention must be paid to each factory power supply overhaul!).
Recomendaciones relacionadas
-
Operation and Maintenance of Small Water Chiller Units
9272. Air-cooled module internal filter, in order to better filter impurities in the water system, the protective plate heat exchanger is generally more than 40 meshes, that is to say, its filter is more dense and finer than other brands. The advanta...
Ver detalles -
¿Por qué hay aire en el sistema de control de temperatura del reactor?
942El gas de impurezas en el sistema de control de temperatura del reactor es para aumentar la presión de condensación del sistema de refrigeración, aumentando así la temperatura de condensación, el aumento de la temperatura de escape del compresor, el aumento de la poten...
Ver detalles -
Relación Entre La Temperatura De Condensación Y La Temperatura De Condensación En Ultrabaja Temperatura
1287La temperatura de enfriamiento de los refrigeradores de recirculación a temperatura ultrabaja se refiere a la temperatura a la que el estado de la sustancia cambia de estado gaseoso a estado líquido bajo una determinada presión. Diferentes sustancias tienen diferentes...
Ver detalles -
Model and size selection of cooling and heating circulator (pilot plant temperature control system)
1055The cooling and heating circulator adopts mechanical refrigeration, the low-temperature heating tube heats the high temperature, and the canned pump is used as the circulating pump. The liquid circulation of the whole system is closed and consists...
Ver detalles