Inspección de mantenimiento de la unidad de refrigeración de baja temperatura
Low-temperature refrigeration units usually need to do a maintenance. After the maintenance is done, it is not easy to fail, and there will be more markets. If it is not easy to fail, it will not stop working, which is equivalent to saving the company’s cost. It should be noted that the low-temperature refrigeration unit is maintained. It is very important to lubricate the industrial machinery at ordinary times, because it is always in operation, and the parts that run frequently must be lubricated regularly. If lubrication is not added, the friction will be large. The parts are worn out, so they should be observed and inspected regularly.
Different configurations use different lubricants:
If a problem with the low-temperature refrigeration unit is found, it should be replaced immediately. Different configurations require different lubricating oil. Remember to use special lubricating oil, don’t use a kind of lubricating oil casually. If you use the wrong lubricating oil, the effect of lubricating oil will not be good. It is also possible that the lubricating oil will fall directly from the top when the lubricating oil is just applied. What a role.
Regularly replace the filter drier:
The filter drier should also be replaced. The filter drier is a very important component to ensure the normal circulation of the refrigerant. Water and refrigerant are incompatible with each other. If the system contains water, this will greatly affect the low-temperature freezing The operating efficiency of the unit, so it is very important to keep the system dry. If you want the internal dry, you need to replace the filter element inside the filter regularly.
Regularly check the pipeline for scale:
One of the usual maintenance of low-temperature refrigeration units should also pay attention to check whether the pipeline has deposited scale? If there is too much scale, it will significantly affect the heat transfer. The contact surface of cooling water will also shrink, the quantity will decrease, and the condensing pressure will increase. Usually, it is necessary to use tap water to use a water-cooled chiller. The quality of tap water in different regions of our country is different. Some are alkaline and some are alkaline. If the sex is small, some have more impurities, some have less impurities, and if there are more impurities for a long time, some very obvious scales will easily appear, and the effects we have just mentioned will appear.
To Sum Up
We need to carry out regular maintenance and inspection of the equipment, which can not only improve the efficiency of the machine but also save costs.
Recomendaciones relacionadas
-
Efficient method for extracting total cannabinoids using a cryogenic process cooling system
1808Although cannabis plants have been used for medicinal purposes for thousands of years, modern science has identified steroids, flavonoids and more than 100 therapeutically active compounds known as cannabinoids. Due to the significant synergy betw...
Ver detalles -
Pequeño golpe para tratar el bloqueo por hielo de los enfriadores de circulación de líquido de alta y baja temperatura
1297En el funcionamiento de las enfriadoras por circulación de líquido de alta y baja temperatura, el atasco de hielo es un fallo relativamente común. Basándonos en la experiencia de los fabricantes pertinentes, hemos recopilado especialmente consejos relevantes para solucionar los atascos de hielo. En la tubería...
Ver detalles -
Motor test bench test and temperature system for vehicle components
2229All vehicle components must undergo rigorous testing, but safety programs must undergo more stringent durability and terminal testing. Many physical methods can be used to load the motor, but the small motor test bench is favored for its high spee...
Ver detalles -
Consejos de marca del ultracongelador
1404Cuando se trata de congeladores de temperatura ultra baja, la mayoría de las personas se preocupan porque la temperatura ultra baja significa que la tecnología se vuelve más difícil. En comparación con otras plantas de refrigeración, las opciones de congelador de temperatura ultra baja...
Ver detalles
LNEYA Enfriadoras industriales Fabricante Proveedor