LNEYA semiconductor refrigeration unit common fault description
If a high-voltage alarm occurs in the semiconductor refrigeration unit, it is necessary to check whether the external piping is blocked or dirty. Clean and remove in time. If it is an air-cooled semiconductor refrigeration device, it is necessary to check the space ventilation condition of the semiconductor refrigeration device. If the space is small and the ventilation is not good, it is easy to cause a high-pressure alarm. In addition, if the compressor discharge pressure is too high, pressure relief is required. Turn on the pressure relief valve and put some gas on it.
Leakage refrigerant is one of the more common faults in semiconductor refrigeration equipment. There are many causes of refrigerant leakage in refrigeration systems of semiconductor refrigeration equipment, mainly in the welding area, which has its own manufacturing problems and is caused by customers. Leaking the refrigerant directly causes the semiconductor refrigeration unit to be unable to cool, and it is necessary to check for leaks. Check that it is leaking refrigerant in that place, and then make it up.

The low-temperature alarm and leakage refrigerant of the semiconductor refrigeration device are closely related. The first thing to do is to check whether the refrigerant is leaking. Most of the low-voltage conditions are caused by the leakage of the refrigerant in the semiconductor refrigeration device. Therefore, it is necessary to check the refrigerant and still need to check for leaks. If the compressor of the semiconductor refrigeration unit does not work, it is necessary to check whether the water pump of the semiconductor refrigeration device is good or bad. If the water pump is good, it is necessary to see if the water in the semiconductor refrigeration device tank can be replenished, and then check the current.
Since the semiconductor industry has certain requirements for the operation efficiency of the semiconductor refrigeration device, it is better for the semiconductor refrigeration device to avoid these faults as much as possible.
Recomendaciones relacionadas
-
¿Cómo sustituir el compresor scroll del modelo de impactómetro?
1457En términos de diferentes modelos de probador de impacto, la configuración también es algo diferente. Entre ellos, se debe tener especial cuidado al sustituir la voluta es un compresor. Si la sustitución no se nota, el probador de impacto no se puede utilizar. El ...
Ver detalles -
Vocs exhaust gas condensation recovery unit refrigerant charging instructions
1080In the vocs exhaust gas condensation recovery process, the refrigerant is able to affect the operation of the vocs exhaust gas condensation recovery process, vocs exhaust gas condensation recovery treatment professional manufacturers reminded that...
Ver detalles -
Aplicación y función del sistema de circulación a temperatura constante a prueba de explosiones
962El control de la temperatura en la investigación y el desarrollo de fármacos y en experimentos químicos, así como el control de la temperatura en la producción experimental a pequeña escala y en la producción industrial, requieren reguladores de temperatura constante altamente dinámicos. La química...
Ver detalles -
The Method That Small Water Cooled Chiller Needs To Follow When Charging Refrigerant
1124In our life, we believe that everyone is very familiar with refrigeration. In the central air conditioning and industrial production process cooling industry, small water cooled chiller is more common. This unit is composed of a compressor in the ...
Ver detalles