How to choose a power battery test evaporator?
The corrosion of ferrous metals by salt water is very strong, and its corrosion is more severe when it comes into contact with air. Therefore, as far as the production process permits, closed loops should be used as much as possible. For volatile refrigerant circulation systems, a closed cycle must be used. In both cases, the horizontal battery tube evaporator is a suitable choice for the power battery test group. The tank immersed evaporator is used in an open circulation system with a non-volatile coolant. This type of evaporator is preferred for production processes that use iced ice cubes to make ice. Water tank immersed evaporators can also be used for power battery test refrigeration systems that cool or freeze bagged food in brine and concentrated spray air conditioning.
When the power battery test uses a tank immersed or shell-and-tube evaporator, the working temperature of the brine should be about 5 °C higher than the refrigerant evaporator temperature, and the freezing point of the brine should be 5-8 lower than the refrigerant evaporation temperature. °C (take 5 to 6 °C for the tank immersed evaporator and 6 to 8 °C for the shell and tube evaporator). For the power battery test, the cooling fan is usually used to increase the cooling temperature. For the freezing of the small cold storage, the shelf type pipe or the wall pipe and the top pipe can be used. For the low-evaporation power battery test evaporator, Note the effect of the height of the refrigerant liquid column on the evaporative temperature of the power battery test. The lower the evaporation temperature, the greater the influence of the liquid column. Therefore, certain measures should be taken to reduce the height of the liquid column in the evaporator.
The operation of the evaporator for the power battery test is relatively convenient, so it is better to choose the evaporator of the brand as much as possible.
Recomendaciones relacionadas
-
Reacción química exotérmica o endotérmica Sistema de compensación dinámica de la temperatura
1687In the chemical laboratory, pilot plant and reaction process, temperature control requires the use of dynamic temperature control systems. When controlling the reactor, the exothermic and endothermic reactions must be compensated with high speed a...
Ver detalles -
Consejos de mantenimiento diario para enfriadoras de recirculación a temperatura ultrabaja?
1504Para garantizar el funcionamiento normal de los enfriadores de recirculación a temperatura ultrabaja después de la puesta en marcha, es necesario asegurarse de que el condensador del enfriador de recirculación a temperatura ultrabaja tenga una buena disipación de calor, de lo contrario la protecci...
Ver detalles -
Semiconductor refrigeration temperature control table cooler operation instructions
1820The power supply switching of the control system of the transformer cooling system of the semiconductor refrigeration temperature control station uses the imported dual power automatic switching device. Its main function is automatic switching bet...
Ver detalles -
What is a laboratory glycol chiller What should I pay attention to
1951The laboratory glycol chiller is a commoncooling equipment in the laboratory. It is generally used to achieve thetemperature requirement of the cold source. What are the benefits?1. Why choose a laboratory glycol chiller:The single-machine self-...
Ver detalles
LNEYA Enfriadoras industriales Fabricante Proveedor