Summary of Maintenance Items of Glycol Chiller
During the daily operation of glycol chiller, if the maintenance is not in place, the cooling effect of glycol chiller will be reduced. Therefore, in order to improve the operation efficiency of glycol chiller, we suggest that you should carry out necessary daily maintenance.

Inspection of refrigeration system of glycol chiller: generally, various problems will inevitably occur after long-term use of glycol chiller. Once there is a fault, we should carefully check the service condition of various parts of the machine, focusing on the refrigeration system, electrical system, air system and water system, and judge whether their functions are normal. We usually check them through sound and appearance. If there are problems, we suggest to replace them in time.
Refrigerant inspection of glycol chiller: regularly check whether the refrigerant of glycol chiller leaks: it can be determined by referring to the parameters displayed on the high and low pressure meter on the front panel of the host. According to the temperature change of air temperature (winter and summer), the pressure display of glycol chiller is also different. When the low-temperature chiller works normally, the high-pressure display is 11-17kg and the low-pressure display is 3-5kg.
Inspection of cooling water system of glycol chiller: check whether the cooling water system of glycol chiller is normal, whether the fan and sprinkler shaft of cooling water tower operate well, and whether the make-up water of the built-in water tank of chiller is normal.
System cleaning of glycol chiller: the glycol chiller shall be cleaned once a year after six months of use. The main cleaning parts include cooling water tower, cooling water pipe and condenser to ensure good refrigeration effect.
Voltage and current inspection of glycol chiller: regularly check whether the voltage and electric flow of glycol chiller are stable and whether the compressor operates normally. When the glycol chiller works normally, the voltage is 380V and the current is in the range of 11a-15a.
Of course, there are many other details that need your attention.
Recomendaciones relacionadas
-
What are the functions of the reactor temperature control system?
981The reactor temperature control system is equipped with various reactors for high and low temperature reflection of liquid and solid. The temperature control system of LNEYA reactor adopts fully closed circulation pipeline, which is efficient in o...
Ver detalles -
Why can ethylene glycol chillers be used for polymerization and coupling reactions
8911. Polymerization heatingGenerally, the raw materials ofpolymerization reaction are some flammable solvents, and heating up quickly maycause local temperature to be too high and cause accidents. Everypolymerization reaction has its proper react...
Ver detalles -
Solución a los fallos de alta y baja presión en enfriadoras por agua
1171El método para eliminar las deficiencias de alta y baja presión del enfriador refrigerado por agua siempre ha sido un punto clave y una dificultad en la industria, por lo que es muy importante dominar las soluciones a las deficiencias de alta y baja presión de w...
Ver detalles -
Cómo hacer que los refrigeradores de recirculación a temperatura ultrabaja ahorren más energía
1056In modern times, environmental protection and energy saving is the development theme, so is the industrial chiller. Then, how to improve your industrial chiller to be more energy conservation? First, to prevent and reduce the pipe scaling of indus...
Ver detalles