Function of Water Pump of Industrial Water Chiller
The water pump is one of the important auxiliary components of the refrigeration system of the industrial water chiller. Many industries will use the industrial water chiller, but many people don’t know much about the equipment. This time, lneya refrigeration will talk about the role of the water pump of the industrial water chiller.

The function of the water pump of the industrial water chiller is to provide pressure and water flow according to the needs of the system. The chilled water pump is the water pump, also known as the circulating water pump. Of course, the chilled water pump is not only the water pump in the industrial water chiller system, but also may exist in the cooling water system of the air-cooled water chiller.
The water pump of industrial water chiller can determine the water flow of chilled water, that is, the water flow of chilled water is not only affected by the size and capacity of the water tank, but also affected by the chilled water pump. The water flow can determine the range of refrigeration temperature to some extent. When the same cooling capacity is transmitted with chilled water as refrigerant, the larger the water flow is, the higher the temperature of the cooling capacity will be.
Water flow is controlled by chilled water pump, so there is a close relationship between chilled water pump and industrial water chiller refrigeration. The specific reasons are as follows: while the water flow of the industrial water chiller increases, the cooling capacity of the chilled water per unit area will decrease. Although the total cooling capacity remains unchanged, the cooling capacity per unit area of the chilled water has decreased. Therefore, if the chilled water flow is large, the cooling effect will become worse and the temperature will become higher, However, this does not mean that the refrigeration capacity of the compressor and the whole chiller system becomes worse.
The chilled water system includes water pipeline, chilled water tank, water pump, etc. the specific parameter selection and xing’shi selection of the water pump are closely related to the model of the industrial chiller. Whether the type of the water pump and the parameter model can be selected will directly determine the refrigeration capacity of the industrial chiller and even whether the industrial chiller can work normally.
About the role of industrial water chiller water pump, that’s it. If you don’t understand, please consult us!
Recomendaciones relacionadas
-
Precautions for safe use of heat transfer oil temperature control equipment
1001With the extensive use of thermal oil temperature control equipment, the safe use of thermal oil temperature control equipment is a concern for users. For manufacturers, it is very important to share the precautions for the use of thermal oil temp...
Ver detalles -
Maintenance of the Condenser in Low Temperature Chillers
910In recent years, with the improvement of China's industrial production level, many professional industrial machinery and equipment provide greater help for different industrial production. As a very practical industrial refrigeration equipment, l...
Ver detalles -
Selection method of 0℃~5℃ freezing liquid for industrial ultra-low temperature chiller
929As the requirements for process production become higher and higher, industrial ultra-low temperature chillers are required to provide cryogenic liquid below 5 degrees or even more than minus 100 degrees in some chemical process synthesis, reactor...
Ver detalles -
Failures of Heating Cooling Circulators
964The heating cooling circulator can be used in many chemical pharmaceuticals and laboratories. Then, how to solve the failures of the heating cooling circulator?Failure of circulating pumpThe failure of the circulating pump is generally the heat ov...
Ver detalles