The Difinition and Application of Heating Cooling Circulator
Before discussing how to choose the right brand of heating cooling circulator, we need to know the definition and application of heating and cooling circulator.
Definition: thermostatic waterbath is also called the thermostatic water tank, constant temperature water tank, constant temperature circulator, heating cooling circulator, refrigeration and heating bath circulation, constant temperature circulation system and so on, is on the basis of the water bath pot increased water circulation and cooling function, can improve the precision of temperature control and temperature stability, we mainly silicone oil as a bath when the temperature higher than 100 degrees, room temperature to 100 degrees with water as a bath, below 0 degrees we use alcohol as a bath.
Application: the heating cooling circulator can be widely used in drying, concentration, distillation, impregnation of chemical reagents, impregnation of drugs and biological products, can also be used in water bath thermostatic heating and other temperature test; Through the hose connected to other equipment, used as a source of constant temperature, such as rotary evaporator, electrophoresis system capillary, transblot system, chest, viscometer, fermentation tank, electrophoresis system capillary, transblot system, chest, column chromatography, spectrophotometer, refractometer, polarimeter, medical cold cap, cooling blanket, etc. Or for circulating cooling of other equipments such as power supply, ion pump, diffusion pump, molecular pump, microwave therapy apparatus, etc., providing a field source with controlled heating and cooling, uniform and constant temperature
Recomendaciones relacionadas
-
Use and maintenance of laboratory/bioengineering temperature control system
15841. Read the equipment manual carefully before use, get familiar with the operation process and key instructions, and operate in strict accordance with the conditions specified in the manual. 2. When moving the laboratory/bioengineering temperatur...
Ver detalles -
High temperature test equipment related troubleshooting
1743The high temperature test equipment is mostly caused by water shortage in the water circulation. This way, the purified water is replenished to the water tank until the water level meter on the lower right side of the water tank reaches about 80% ...
Ver detalles -
Maintenance method of minus 17 ° C ultra-low temperature refrigerator
1737After the long-term use of the ultra-low temperature refrigerator of minus 17 °C, it is necessary to carry out certain maintenance work. If the user does not know how to carry out the maintenance work, you can contact the manufacturer to obtain th...
Ver detalles -
Puntos principales del mantenimiento del termostato de refrigeración de temperatura ultrabaja LNEYA
1724Ultra-low temperature refrigeration circulators need to be maintained after a long period of operation, so what aspects should be paid attention to? Check and maintain the ultra-low temperature refrigeration circulator on time. It can find problem...
Ver detalles
LNEYA Enfriadoras industriales Fabricante Proveedor