LNEYA tratamiento del llanto superprofundo con sentido común
For ultra-deep cold processing equipment, failure to pay attention to the use of the equipment may cause equipment failure.
Before using the water-cooled ultra-cry cryogenic treatment, it should be checked whether all the valves between the equipments are open, whether all the water tanks are filled with water, whether the fans are reversed, and whether the circulating water pump is running in the correct direction. Open the super deep crying treatment main power supply (the standard power supply is 3-phase five-wire system 380V 50HZ), specifically the water-cooled ultra-deep cold treatment front nameplate. Wuxi Guanya LNEYA reminds everyone that the power supply for ultra-deep cooling must be stable to avoid burning the unit or compressor and pump motor.
First open the ultra-deep cooling treatment cooling switch, then turn on the chilled water pump switch. Since the compressor has a delayed start function, the compressor will automatically run after the delay. At this time, pay close attention to the front control panel to observe the temperature change, as appropriate according to the cooling demand. Perform temperature adjustment. Water-cooled ultra-cry cryogenic treatment During normal operation, the unit operation data should be recorded periodically to facilitate the identification of problems based on data as soon as the unit fails. The ultra-cryogenic treatment itself is provided with multiple protection devices. Once there is a fault, it will start to protect and automatically stop. After the fault is removed, press the reset to operate normally.
When the super-cryogenic treatment is not used, the unit, water pump, insulated water tank and water in the pipeline should be drained, and the equipment should be covered and protected to avoid dust and other debris. Regarding the maintenance of ultra-deep cold treatment, this cannot be ignored. It is necessary to clean the condenser and evaporator after running for half a year. It is recommended to carry out maintenance of the whole machine after one year of operation, and keep it clean and clean regularly.
The instruction manual of the ultra-cryogenic treatment equipment and regular inspection and maintenance are all parts that the user needs to know in order to make the equipment run more efficiently.
Recomendaciones relacionadas
-
Las empresas deben tener en cuenta varios aspectos importantes al utilizar refrigeradores de calefacción
1788Además de las empresas antes mencionadas, que deben organizar para que alguien sea responsable de la puesta en marcha y parada de refrigeradores, interruptores, y las reparaciones y el mantenimiento. Las precauciones para el uso de refrigeradores en las empresas son las siguientes...
Ver detalles -
Detalles del dispositivo de protección del dispositivo de control de la temperatura del fluido circulante
1847La función de protección contra sobrecarga de la bomba de circulación consiste en cortar la alimentación principal de la bomba de circulación cuando el dispositivo de ajuste de la temperatura del líquido circulante es demasiado grande. Pulse el botón verde al restablecer; el botón rojo es el botón de parada....
Ver detalles -
Instrucciones de detección de fallos del compresor del termostato semiconductor de calefacción y refrigeración
1338In the semiconductor heating and cooling thermostat, the compressor is one of its core components. Once it fails, it will affect the operation of the whole system. How to solve the fault is better? The faults of semiconductor heating and cooling t...
Ver detalles -
Las ventajas de la enfriadora por agua que debe conocer
1780Los refrigeradores industriales pueden dividirse generalmente en refrigerados por agua y refrigerados por aire según el tipo de refrigeración. El medio de intercambio de calor de los enfriadores refrigerados por agua es el agua.LNEYA ha diseñado y desarrollado un nuevo tipo de equ...
Ver detalles
LNEYA Enfriadoras industriales Fabricante Proveedor