air cooled chiller – LNEYA Industrial Chillers Manufacturer Supplier https://www.lneya.com/es Enfriadoras de aire y de agua Thu, 22 May 2025 08:46:46 +0000 es por hora 1 https://wordpress.org/?v=6.8.2 https://www.lneya.com/wp-content/uploads/2024/05/logo-lneya-150x150.jpg air cooled chiller – LNEYA Industrial Chillers Manufacturer Supplier https://www.lneya.com/es 32 32 How to Select Air Cooled Chiller and Water Cooled Chiller? https://es.lneya.com/blog/how-to-select-air-cooled-chiller-and-water-cooled-chiller.html https://es.lneya.com/blog/how-to-select-air-cooled-chiller-and-water-cooled-chiller.html#respond Thu, 22 May 2025 08:31:15 +0000 https://www.lneya.com/?p=13845

How to Select Air Cooled Chiller and Water Cooled Chiller?and Different?

Enfriadoras Components

LNEYA have air cooled chiller type and water cooled chiller type
LNEYA have air cooled chiller type and water cooled chiller type

Chiller Efficiency

Water-cooled chillers have higher cooling efficiency! Why?

Chiller Capacity

Chiller Locations

The cost of a chiller includes purchase cost, operating cost and maintenance cost
The cost of a chiller includes purchase cost, operating cost and maintenance cost

Chiller Installation

Chiller Maintenance

You need to regularly maintain the major components and unique parts of both air-cooled and water-cooled chillers.

  • Air-cooled chiller-You should check the fan’s operation regularly and clean the dust from the fan blades and condenser fins. If you use a filter, clean or replace it as well.
  • Water-cooled chiller-It requires clean cooling water, so you need to regularly test the cooling water quality, check the water pump and clean the water tower. The water in the water tower will evaporate, and you have to replenish the cooling water. And if you use a shell and tube heat exchanger, its inner wall is prone to fouling, so you also need to clean it regularly.

Chiller Life Expectancy

  • Water-cooled chiller-The average life of a water-cooled chiller is usually 20 to 30 years.

Chiller Cost

Need Air Cooled Chiller or Water Cooled Chiller?

Refrigeradores recomendados

outdoor chillers

Potencia de calefacción 3,5 kW~15 kW

temperature accuracy ±0.3℃

large water chillers

Heating power 2.5kW~10kW

temperature accuracy ±0.3℃

screw water chillers

Circulation Pump MAX 5m³/h~28m³/h 2bar

precisión de temperatura ±0,5℃

]]>
https://es.lneya.com/blog/how-to-select-air-cooled-chiller-and-water-cooled-chiller.html/feed 0
LT -80℃~-20℃ https://es.lneya.com/industrial-chiller/lt-water-chiller-80.html https://es.lneya.com/industrial-chiller/lt-water-chiller-80.html#comments Sun, 27 Oct 2024 07:32:33 +0000 https://www.lneya.com/industrial-chillers/lt-water-chiller-80.html

Industrial Air Chiller Unit

LT -80℃~-20℃
LT -80℃~-20℃
LT -80℃~-20℃
LT -80℃~-20℃

LT -80℃~-40℃

  • Capacidad de refrigeración0.4kW~2.5kW
  • Almacenamiento de líquidos15L~60L
  • RefrigeranteR404A/R508B
  • Peso185KG~470KG
  • Lugar de origenChina

Descripción del producto

1. Puede utilizar etilenglicol mezclado con agua para la refrigeración circulante, ahorrando recursos.

2. Diseño de tubería de circulación, prolongar el tiempo de uso del agua circulante.

3. Adopta compresor de marca, tecnología de refrigeración de subenfriamiento en cascada.

4. Sistema de condensación doble de alta eficiencia

5. Controlador de temperatura en cascada por ordenador, pantalla digital de temperatura, unidad de ajuste 0.1℃

6. Adopta tecnología de superenfriamiento para garantizar la estabilidad de la temperatura a baja temperatura

7. Se puede ajustar para encender el compresor y apagar la diferencia de temperatura del compresor.

  • 1、Pantalla táctil en color LCD
  • 2、Indicador de nivel de líquido, que muestra la posición del medio de transferencia de calor
  • 3、Entrada y salida del medio de transferencia de calor, arriba hacia fuera y abajo hacia dentro.
  • 4、Medidor de presión, que muestra la presión del sistema de refrigeración
  • 5、Entrada y salida de agua de refrigeración, por arriba y por abajo (refrigeración por agua)
  • 6、Interfaz de comunicación (PT100 estándar, USB, RS485, interfaz Ethernet opcional, RS232, etc.)

Modelo LT8-1.5H LT8-2 LT8-3 LT8-5
LT8-1.5W LT8-2W LT8-2W LT8-5W
Temperatura  -75℃~-40℃ -80℃~-40℃
Control de la temperatura ASET multi-function controller 4.3-inch touch screen
Precisión del control de temperatura ±0.5℃
Retroalimentación de temperatura Retroalimentación de temperatura PT100 (temperatura de entrada, temperatura de salida)
Capacidad de refrigeración -60℃ 0,7 kW 1kw 1,4 kW 2,5 kW
-70℃ 0.4kw 0.6kw 0.85kw 1,5 kW
Circulation pump MAX 30L/min 1.6bar 30L/min 1.6bar 30L/min 1.6bar 30L/min 1.6bar
Compresor Hitachi, Emerson Copeland and other compressors
Evaporador Intercambiador de placas
Panel de control 4.3-inch color touch screen displays set temperature and measured temperature, records temperature curve, and data is exported in Excel format
Protección de seguridad With self-diagnosis function; refrigerator overload protection; high and low pressure sensors, overload relays, thermal protection devices and other safety protection functions.
Refrigerante R-404A   R23
Tamaño de la interfaz ZG3/4 ZG3/4 ZG3/4 ZG3/4
Alimentación AC220V / AC380V/ AC460V
Material de la carcasa Cold rolled sheet spraying (REL7035)
  Communication protocol MODBUS RTU protocol RS485 interface

Aplicaciones de los productos

Envíenos un mensaje sobre LT-80℃
*
*
正在提交中....
提交成功!
提交失败!请稍后再试
邮箱错误!
电话错误!

Recomendar productos

cargando...

已经是到最后一篇内容了!

]]>
https://es.lneya.com/industrial-chiller/lt-water-chiller-80.html/feed 3
LT -45℃~30℃ https://es.lneya.com/industrial-chiller/low-temperature-refrigeration-circulator/air-cooled-water-chiller-system-lt1.html https://es.lneya.com/industrial-chiller/low-temperature-refrigeration-circulator/air-cooled-water-chiller-system-lt1.html#respond Tue, 27 Feb 2024 07:32:45 +0000 https://www.lneya.com/industrial-chillers/air-cooled-water-chiller-system-lt1.html

LT -45℃~30℃
LT -45℃~30℃
LT -45℃~30℃
LT -45℃~30℃

LTZ -45℃~30℃

  • Capacidad de refrigeración0.75kW~4.8kW
  • Gama de potencia1,6 kW~8 kW
  • Almacenamiento de líquidos15L~80L
  • RefrigeranteR404A/R507C
  • Peso145KG~380KG
  • Lugar de origenChina

LOW TEMPERATURE

COOLING CIRCULATOR

Detalles de configuración

Modelo LT4-1.5 LT4-2 LT4-3 LT4-5
LT4-1.5W LT4-2W LT4-2W LT4-5W
Temperatura  -37℃~30℃  -45℃~30℃
Control de la temperatura ASET multi-function controller 4.3-inch touch screen
Precisión del control de temperatura ±0.5℃
Retroalimentación de temperatura Retroalimentación de temperatura PT100 (temperatura de entrada, temperatura de salida)
Capacidad de refrigeración -20℃ 1,3 kW 1,8 kW 2,5 kW 4.8kw
-35℃ 0,7 kW 1kw 1,4 kW 2,5 kW
Circulation pump MAX 30L/min 1.6bar 30L/min 1.6bar 30L/min 1.6bar 30L/min 1.6bar
Compresor Hitachi, Emerson Copeland and other compressors
Evaporador Intercambiador de placas
Panel de control 4.3-inch color touch screen displays set temperature and measured temperature, records temperature curve, and data is exported in Excel format
Protección de seguridad With self-diagnosis function; refrigerator overload protection; high and low pressure sensors, overload relays, thermal protection devices and other safety protection functions.
Refrigerante R-404A  /  R507C
Tamaño de la interfaz ZG3/4 ZG3/4 ZG3/4 ZG3/4
Alimentación AC220V / AC380V/ AC460V
Material de la carcasa Cold rolled sheet spraying (REL7035)
  Communication protocol MODBUS RTU protocol RS485 interface

Descripción del producto

1. Puede utilizar etilenglicol mezclado con agua para la refrigeración circulante, ahorrando recursos.

2. Diseño de tubería de circulación, prolongar el tiempo de uso del agua circulante.

3. Adopta compresor de marca, tecnología de refrigeración de subenfriamiento en cascada.

4. Sistema de condensación doble de alta eficiencia

5. Controlador de temperatura en cascada por ordenador, pantalla digital de temperatura, unidad de ajuste 0.1℃

6. Adopta tecnología de superenfriamiento para garantizar la estabilidad de la temperatura a baja temperatura

7. Se puede ajustar para encender el compresor y apagar la diferencia de temperatura del compresor.

Aplicaciones de los productos

Haga clic en el mensaje en línea para consultar los detalles del producto
Envíenos un mensaje sobre el producto
*
*
正在提交中....
提交成功!
提交失败!请稍后再试
邮箱错误!
电话错误!

recomendar productos

cargando...

已经是到最后一篇内容了!

]]>
https://es.lneya.com/industrial-chiller/low-temperature-refrigeration-circulator/air-cooled-water-chiller-system-lt1.html/feed 0
LT -60℃~-20℃ https://es.lneya.com/industrial-chiller/lt-water-chiller-20.html https://es.lneya.com/industrial-chiller/lt-water-chiller-20.html#respond Tue, 27 Feb 2024 07:32:39 +0000 https://www.lneya.com/industrial-chillers/lt-water-chiller-20.html

LT -60℃~-20℃
LT -60℃~-20℃
LT -60℃~-20℃
LT -60℃~-20℃

LT -60℃~-20℃

  • Capacidad de refrigeración0,4 kW~6 kW
  • Gama de potencia3kW~9kW
  • Almacenamiento de líquidos15L~60L
  • RefrigeranteR404A/R23
  • Peso145KG~380KG
  • Lugar de origenChina

Circulating refrigeration of ethylene glycol mixed with water mixture

After the medium enters the extraction tank, it must be closed,the sandwich is heated, and the refrigerant is turned on to reducethe heat source of the boiling tank, and the steam is cooled backto the tank to maintain circulation and temperature.

Detalles de configuración

Modelo LT6-1.5H LT6-2 LT6-3 LT6-5
LT6-1.5W LT6-2W LT6-2W LT6-5W
Temperatura  -60℃~-30℃
Control de la temperatura ASET multi-function controller 4.3-inch touch screen
Precisión del control de temperatura ±0.5℃
Retroalimentación de temperatura Retroalimentación de temperatura PT100 (temperatura de entrada, temperatura de salida)
Capacidad de refrigeración -40℃ 1,3 kW 1,8 kW 2,5 kW 4.8kw
-55℃ 0,7 kW 1kw 1,4 kW 2,5 kW
Circulation pump MAX 30L/min 1.6bar 30L/min 1.6bar 30L/min 1.6bar 30L/min 1.6bar
Compresor Hitachi, Emerson Copeland and other compressors
Evaporador Intercambiador de placas
Panel de control 4.3-inch color touch screen displays set temperature and measured temperature, records temperature curve, and data is exported in Excel format
Protección de seguridad With self-diagnosis function; refrigerator overload protection; high and low pressure sensors, overload relays, thermal protection devices and other safety protection functions.
Refrigerante R-404A   R23
Tamaño de la interfaz ZG3/4 ZG3/4 ZG3/4 ZG3/4
Alimentación AC220V / AC380V/ AC460V
Material de la carcasa Cold rolled sheet spraying (REL7035)
  Communication protocol MODBUS RTU protocol RS485 interface

condiciones: temperatura de bulbo seco: 20℃; temperatura de bulbo húmedo: 16℃. Temperatura del agua de entrada: 20℃; temperatura del agua de salida: 25℃.

Los datos de esta tabla son solo de referencia. Consulte los parámetros de la placa de identificación de la unidad.

Si necesita una personalización especial no estándar, contáctenos.

Descripción del producto

1. Puede utilizar etilenglicol mezclado con agua para la refrigeración circulante, ahorrando recursos.

2. Diseño de tubería de circulación, prolongar el tiempo de uso del agua circulante.

3. Adopta compresor de marca, tecnología de refrigeración de subenfriamiento en cascada.

4. Sistema de condensación doble de alta eficiencia

5. Controlador de temperatura en cascada por ordenador, pantalla digital de temperatura, unidad de ajuste 0.1℃

6. Adopta tecnología de superenfriamiento para garantizar la estabilidad de la temperatura a baja temperatura

7. Se puede ajustar para encender el compresor y apagar la diferencia de temperatura del compresor.

  • 1、Pantalla táctil en color LCD
  • 2、Indicador de nivel de líquido, que muestra la posición del medio de transferencia de calor
  • 3、Entrada y salida del medio de transferencia de calor, arriba hacia fuera y abajo hacia dentro.
  • 4、Medidor de presión, que muestra la presión del sistema de refrigeración
  • 5、Entrada y salida de agua de refrigeración, por arriba y por abajo (refrigeración por agua)
  • 6、Interfaz de comunicación (PT100 estándar, USB, RS485, interfaz Ethernet opcional, RS232, etc.)

Aplicaciones de los productos

Envíenos un mensaje sobre LT -60℃
*
*
正在提交中....
提交成功!
提交失败!请稍后再试
邮箱错误!
电话错误!

recomendar productos

cargando...

已经是到最后一篇内容了!

]]>
https://es.lneya.com/industrial-chiller/lt-water-chiller-20.html/feed 0
LT -25℃~30℃ https://es.lneya.com/industrial-chiller/low-temperature-refrigeration-circulator/lt-air-chiller-25.html https://es.lneya.com/industrial-chiller/low-temperature-refrigeration-circulator/lt-air-chiller-25.html#comments Tue, 27 Feb 2024 07:32:20 +0000 https://www.lneya.com/industrial-chillers/lx-water-chiller-25.html

LT -25℃~30℃
LT -25℃~30℃
LT -25℃~30℃
LT -25℃~30℃

LT -25℃~30℃

  • Gama de potencia1,5 kW~17 kW
  • Almacenamiento de líquidos15L~300L
  • RefrigeranteR404A
  • Peso115KG~950KG
  • Lugar de origenChina
  • Capacidad de refrigeración0,8 kW~30 kW

100% safety regulations

Detalles de configuración

Modelo LT2-1.5 LT2-2 LT2-3 LT2-5
LT2-1.5W LT2-2W LT2-2W LT2-5W
Temperatura  -25℃~30℃
Control de la temperatura ASET multi-function controller 4.3-inch touch screen
Precisión del control de temperatura ±0.5℃
Retroalimentación de temperatura Retroalimentación de temperatura PT100 (temperatura de entrada, temperatura de salida)
Capacidad de refrigeración -15℃ 1,5 kW 2kw 3kw 5kw
Circulation pump MAX 30L/min 1.6bar 30L/min 1.6bar 30L/min 1.6bar 30L/min 1.6bar
Compresor Hitachi, Emerson Copeland and other compressors
Evaporador Intercambiador de placas
Panel de control 4.3-inch color touch screen displays set temperature and measured temperature, records temperature curve, and data is exported in Excel format
Protección de seguridad With self-diagnosis function; refrigerator overload protection; high and low pressure sensors, overload relays, thermal protection devices and other safety protection functions.
Refrigerante R-404A  /  R507C
Tamaño de la interfaz ZG3/4 ZG3/4 ZG3/4 ZG3/4
Alimentación AC220V / AC380V/ AC460V
Material de la carcasa Cold rolled sheet spraying (REL7035)
  Communication protocol MODBUS RTU protocol RS485 interface

Descripción del producto

1. Puede utilizar etilenglicol mezclado con agua para la refrigeración circulante, ahorrando recursos.

2. Diseño de tubería de circulación, prolongar el tiempo de uso del agua circulante.

3. Adopta compresor de marca, tecnología de refrigeración de subenfriamiento en cascada.

4. Sistema de condensación doble de alta eficiencia

5. Controlador de temperatura en cascada por ordenador, pantalla digital de temperatura, unidad de ajuste 0.1℃

6. Adopta tecnología de superenfriamiento para garantizar la estabilidad de la temperatura a baja temperatura

7. Se puede ajustar para encender el compresor y apagar la diferencia de temperatura del compresor.

Envíenos un mensaje sobre el producto
*
*
正在提交中....
提交成功!
提交失败!请稍后再试
邮箱错误!
电话错误!

También pueden interesarle estos productos

cargando...

已经是到最后一篇内容了!

]]>
https://es.lneya.com/industrial-chiller/low-temperature-refrigeration-circulator/lt-air-chiller-25.html/feed 1
Serie ZLJ https://es.lneya.com/component-test-temp-control-systems/direct-cooling-zlj-40-15.html https://es.lneya.com/component-test-temp-control-systems/direct-cooling-zlj-40-15.html#respond Thu, 06 Jul 2023 03:10:47 +0000 https://www.lneya.com/?p=6798
ZLJ -40℃~-15℃

ZLJ -40℃~-15℃

Enfriadora por aire para el proceso de producción de semiconductores
  • Compresor1,5 CV~7 CV
  • RefrigentR404A R507C R448
  • Gama de potencia380V 50HZ puede elegir 220V
  • Precisión de la temperatura±0.5℃

Descarga de datos del producto

CHILLER tipo refrigeración directa

Los requisitos de control múltiple se pueden lograr mediante la fusión de varios dispositivos en un armario más grande

Detalles de configuración

Modelo ZLJ-41.0 ZLJ-41,5 ZLJ-42 ZLJ-43 ZLJ-44 ZLJ-46 ZLJ-48
ZLJ-41.0W ZLJ-41,5W ZLJ-42W ZLJ-43W ZLJ-44W ZLJ-46W ZLJ-48W
Temperatura  -40℃~-10℃
Precisión del control de temperatura ±0,5℃ control de la temperatura de evaporación
Método de estrangulamiento Válvula de expansión electrónica
Controlador Siemens PLC
Mostrar registro Pantalla táctil de 7 pulgadas, registro de temperatura, presión del sistema y otra información
Componentes principales Filtro deshidratador Danfoss, electroválvula Castor, sensor de presión Johnson Controls, ventilador EBM (refrigerado por aire), separador de aceite Danfoss/Emerson,
Compresor Secop, Taikang, Emerson, Carlisle
Refrigerante R404A Opcional R507C R448
Refrigeración a alta temperatura Con tecnología de refrigeración directa a alta temperatura de 150 grados, para cumplir el objetivo de capacidad de refrigeración rápida durante el funcionamiento a alta temperatura.
Compresor 7/8CV 1,5 CV 2HP 3HP 4HP 6HP 8HP
Alimentación V 220V 50HZ 380V 50HZ Se puede personalizar 220V

Descripción del producto

El producto expulsa y evapora directamente el refrigerante del sistema de refrigeración en el elemento de control objetivo (intercambiador de calor) para el intercambio de calor, enfriando así el objeto de control objetivo. En comparación con el fluido (gas) transportado al intercambiador de calor, la capacidad de intercambio de calor es generalmente más de 5 veces superior, lo que resulta especialmente adecuado para aplicaciones en las que el área de intercambio de calor del intercambiador de calor es pequeña pero la capacidad de intercambio de calor es grande.

El refrigerador de enfriamiento directo también se puede utilizar como captura de gas, el refrigerante pasa directamente a la trampa para evaporarse, y el gas en el espacio se captura rápidamente a través del efecto de condensación en la superficie de la trampa.

Haga clic en el mensaje en línea para consultar los detalles del producto
Envíenos un mensaje sobre Enfriadora de refrigeración directa
Envíenos un mensaje sobre Enfriadora de refrigeración directa
*
*
正在提交中....
提交成功!
提交失败!请稍后再试
邮箱错误!
电话错误!

recomendar productos

cargando...

已经是到最后一篇内容了!

]]>
https://es.lneya.com/component-test-temp-control-systems/direct-cooling-zlj-40-15.html/feed 0