Buscar en toda la estación

SUNDIZ Variable Frequency Series Cooling Heating Systems

SUNDIZ Variable Frequency Series Cooling Heating Systems

APLICACIONES

Compared with SUNDI refrigeration system, the circulation system adopts variable frequency control, which saves more than 20% energy, reduces noise by more than 5 decibels, and has a small starting current compared to old products.

By increasing the frequency, the refrigeration power is increased and the cooling rate is improved by frequency conversion control of the circulation pump.

SUNDIZ -45℃~250℃

 

 Modelo SUNDIZ4-3
SUNDIZ4-3W
SUNDIZ4-5
SUNDIZ4-5W
SUNDIZ4-10
SUNDIZ4-10W
SUNDIZ4-15W SUNDIZ4-20W SUNDIZ4-30W
Temperatura -45℃~250℃
Potencia calorífica 5,5 kW 7,5 kW 15 kW 25 kW 38 kW 60 kW
Cooling  capacity  kW 250℃ 5,5 kW 7,5 kW 15 kW 25 kW 38 kW 60 kW
20℃ 5,5 kW 7,5 kW 15 kW 25 kW 38 kW 60 kW
-15℃ 2.3kW 3.6kW 7.5 kW 11 kW 15 kW 33kW
-35℃ 0,9 kW 1,5 kW 3.3 kW 5kW 6,5 kW 10kW
Medium temp control accuracy ±0.1℃ ±0.1℃ ±0.1℃ ±0.1℃ ±0.1℃ ±0.1℃
Process temp control accuracy ±0.3℃ ±0.3℃ ±0.3℃ ±0.3℃ ±0.3℃ ±0.3℃
Pump flow rate  pressure max 50 l/min 50 l/min 100L/min 150L/min 250 l/min 400 l/min
2bar 2bar 2bar 2,5 bares 2,5 bares 2,5 bares
Refrigerante R-404A / R507C Optional R448
Tamaño de la interfaz G3/4 G3/4 G1 DN32 PN10 DN40 PN10 DN50 PN10

 

SUNDIZ -80℃~250℃

 

 Modelo SUNDIZ8-3W SUNDIZ8-4W SUNDIZ8-6W SUNDIZ8-10W SUNDIZ8-15W
Temperatura  -80℃~250℃
Potencia calorífica 3,5 kW 5,5 kW 7,5 kW 10kW 15 kW
Cooling  capacity  kW 250℃ 3,5 kW 5,5 kW 7,5 kW 15 kW 20 kW
20℃ 3,5 kW 5,5 kW 7.5 kW 15 kW 20 kW
-60℃ 1.3kW 1,8 kW 3 kW 5,5 kW 8kW
-75℃ 0.4kW 0,6 kW 1 kW 1,8 kW 2.7kW
Medium temp control accuracy ±0.1℃ ±0.1℃ ±0.1℃ ±0.1℃ ±0.1℃
Process temp control accuracy ±0.3℃ ±0.3℃ ±0.3℃ ±0.3℃ ±0.3℃
Pump flow rate  pressure max 35 l/min 50 l/min 100L/min 150L/min 250 l/min
2bar 2bar 2bar 2,5 bares 2,5 bares
Refrigerante R-404A / R508B

 

Common Configuration

 

Visualización de la presión del sistema The pressure of the refrigeration system and circulation system is detected by pressure sensors and displayed on the touch screen
Controlador Siemens S7-1200 PLC, fuzzy PID control algorithm, equipped with process dynamic control algorithm
Control de la temperatura Thermal medium outlet temperature control mode, external temperature sensor: (PT100 or 4-20mA or communication
given) control mode (process dynamic control algorithm)
Programable 25 programs, each program can edit 85 steps
Communication Protocol Ethernet interface TCP/IP protocol, RS485 interface, MODBUS protocol
Internal temp feedback Equipment thermal conductivity medium outlet temperature, medium inlet temperature, refrigeration system condensation
temperature, compressor suction temperature, cooling water temperature (for water-cooled equipment)
External temp feedback Pt100 or 4-20mA or communication given
During cascade control
Temp difference control
function
The temp difference between the outlet temp of the thermal oil and the external temp sensor can be set and controlled
The temp difference between the inlet and outlet of the equipment can be set and controlled to ensure system safety
Closed circulation
sistema
The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature,
pressure do not rise up when system is running. The system will supply oil automatically at low temperature.
Calefacción Se refiere a la potencia máxima de calefacción del sistema (según cada modelo)
El calefactor tiene triple protección y limitador de temperatura independiente para garantizar la seguridad del sistema de calefacción;
Using a voltage regulator to control the heating output and reduce the output current of the heater during process temperature control
External circulation Flow pressure Brand magnetic drive variable frequency pump
Compresor Emerson, Mitsubishi and other variable frequency compressors
Convertidor de frecuencia Famous brands such as ABB
Evaporador 316L Plate Heat Exchanger
Accesorios de refrigeración Danfoss/Emerson accessories (dry filters, oil separators, high and low pressure protectors, expansion valves)
Panel de control LNEYA pantalla táctil en color de 7 pulgadas personalizada, visualización de la curva de temperatura\EXCEL exportación de datos
Protección de seguridad Multiple self-diagnosis function; freezer overload protection; high/low pressure switch; overload relay, thermal protection device etc
Water-cooled condenser Intercambiador de calor de placas
Material de la carcasa Cold rolled sheet (standard color 7035)
Potencia 380V 50HZ / 460V 60HZ

La tecnología de refrigeración de ultra alta temperatura puede enfriar directamente desde una alta temperatura de 300℃[porque sólo el medio de transferencia de calor en la cámara de expansión entra en contacto con el oxígeno en el aire (y la temperatura del tanque de expansión está entre la temperatura normal y 60℃), lo que puede reducir el riesgo de que el medio de transferencia de calor se oxide y absorba agua en el aire. A alta temperatura, ningún medio conductor de calor se evapora, y el control continuo de la temperatura de - 80℃ ~ 190℃, - 70℃ ~ 220℃, - 88℃ ~ 170℃, - 55℃ ~ 250℃ y - 30℃ ~ 300℃ se puede realizar sin presurización.

1. Muestra todos los tipos de temperaturas de control del proceso.
2. Muestra el nivel de líquido del medio conductor del calor en el vaso de expansión.
3. Indicación de funcionamiento del sistema de refrigeración.
4. Muestra la indicación de funcionamiento del calentador.
5. Muestra la indicación de funcionamiento de la bomba de circulación.
6. Muestra el control de temp. ( patrón de control de temp. de materiales, control de temp. media conductora de calor ).
7. Se puede ajustar el control del límite superior e inferior de la temperatura.
8. Se puede ajustar la diferencia de temperatura entre la camisa y el material del reactor.
9. Muestra la alarma para añadir el líquido cuando está vacío.
10. El compresor frigorífico puede funcionar de forma manual o automática.

APLICACIONES

New materials | Special gas production temperature control

API | intermediate production temp control solution

Distillation concentration temperature control solution

Más información

Más información


Desde nuestra fundación en 2006hemos atendido a más de 30.000 clientes y poseemos varias patentes que demuestran nuestra innovación y fiabilidad. Nuestros enfriadores son seleccionados por más de 100 universidad proyectos de laboratorio en todo el mundo y exportados a más de 20 países. Garantizamos la máxima calidad mediante un riguroso 3 pasos proceso de control de calidad: inspección visual, pruebas de rendimiento y pruebas de seguridad eléctrica. Nuestro compromiso con la excelencia está respaldado además por nuestro Atención al cliente 24/7 compromiso de asistencia. Además, contamos con agentes en Estados Unidos, Canadá, Australia, Rusia y Corea del Sur, lo que nos convierte en un socio global de confianza para sus necesidades de enfriadoras. Elija lneya por calidad y asistencia para su proyecto.
18+

Años de experiencia

30000+

Clientes satisfechos

25000

m² Área de producción

80+

Tecnologías patentadas

*
*
Envío....
¡Enviado con éxito!
¡Envío fallido! Vuelva a intentarlo más tarde
Error de correo electrónico.
¡Error telefónico!