Serie WTD Sistema de control de temperatura de refrigeración y calefacción para reactor de microcanal
APLICACIONES
Specially designed and developed for microchannel reactors with low liquid holding capacity, strong heat exchange capacity, and large pressure drop in the circulation system.Continuous high temperature cooling technology to meet the requirements of stable operation when hot and cold constant temperature control is required during high temperature exothermic reactions.
Características del producto
Parámetros del producto
Modelo | WTD-120M | WTD-255 | WTD-455 | WTD-755 | WTD-275V | |
Rango de temperatura | -5°C~120°C | -25°C~200°C | -45°C~250°C | -70°C~200°C | -20°C~300°C | |
Temp accuracy | ±0.3℃ | |||||
Temp resolution | 0.1K | |||||
Control panel | 7 inch colorful touch screen | |||||
Curva de datos | Data Curve Record | |||||
Date output | U disco formato excel | |||||
Control model | PID Adaptive controller | |||||
Comunicación | MODBUS RTU RS485 | |||||
Potencia calorífica | 2kW | 5,5 kW | 5,5 kW | 5,5 kW | 7,5 kW | |
Cooling capacity kW | 300°C | 7,5 kW | ||||
200°C | 5,5 kW | 5,5 kW | 5,5 kW | 7,5 kW | ||
100°C | 1,5 kW | 5,5 kW | 5 kW | 5 kW | 7,5 kW | |
20°C | 1 kW | 5,5 kW | 5 kW | 5 kW | 5,5 kW | |
-15°C | 2,5 kW | 4 kW | 4 kW | 2,5 kW | ||
-35°C | 1,5 kW | 3 kW | ||||
-60°C | 1.1kW | |||||
Bomba de circulación máx. | 7L/min 2,5bar | 25L/min 3bar | 25L/min 3bar | 25L/min 3bar | 25L/min 3bar | |
Tamaño de la conexión | R1/2 | R3/4 | R3/4 | R3/4 | R3/4 | |
Temp sensor | PT100 | PT100 | PT100 | PT100 | PT100 | |
Compresor | Emerson Copeland/Scope/Tecumseh | |||||
Evaporador | Intercambiador de placas | |||||
Cooling way | Refrigerado por aire | Air cooled+water cooled | ||||
Throttle type | Válvula de expansión térmica | Electronic expansion valv | ||||
Filtro seco | Danfoss | |||||
Heating-conduction medium | Synthetic heat conducting oil | |||||
Refrigerante | R404A | R404A | R404A | R404A R23 | R404A | |
Material de los tubos | SUS304 | SUS304 | SUS304 | SUS304 | SUS304 | |
Metal insulated hose | 1m*2 | 1.8M*2 | 1.8M*2 | 1.8M*2 | 1.8M*2 | |
Contactor/circuit breaker | Schneider | Schneider | Schneider | Schneider | Schneider | |
Dimensión cm | 35*56*75 | 55*70*175 | 55*70*175 | 65*85*185 | 55*70*175 | |
Peso en kg | 60KG | 195KG | 205KG | 325KG | 245KG | |
Potencia 380V 50HZ | 220V 3.1kW | 9.5kW MAX | 10kW MAX | 12kW MAX | 15kW MAX | |
Material del maletín | Cold rolled steel powder coating (standard color 7035) |
Modelo | WTD-255-2T Double Temp range WTD-255W-2T Double Temp range |
WTD-455-2T Double Temp range WTD-455W-2T Double Temp range |
|||
Rango de temperatura | -25°C~200°C | -45°C~250°C | |||
Temp accuracy | ±0.3℃ | ||||
Temp resolution | 0.1K | ||||
Control panel | 7 inch colorful touch screen | ||||
Curva de datos | Data Curve Record | ||||
Date output | U disco formato excel | ||||
Control model | PID Adaptive controller | ||||
Potencia calorífica | 5,5 kW | 5,5 kW | 5,5 kW | 5,5 kW | |
Cooling capacity kW | 250°C | 5,5 kW | 5,5 kW | ||
200°C | 5,5 kW | 5,5 kW | 5,5 kW | 5,5 kW | |
100°C | 5kW | 5kW | 5 kW | 5kW | |
20°C | 5kW | 5kW | 5 kW | 5kW | |
-15°C | 2 kW | 2 kW | 4 kW | 4kW | |
-35°C | 1,5 kW | 1,5 kW | |||
Bomba de circulación máx. | 25L/min 3bar Double Line | 25L/min 3bar Double Line | |||
Tamaño de la conexión | R3/4 Double Line | R3/4 Double Line | |||
Temp sensor | PT100 | PT100 | |||
Displays temp. data of two lines of inlet and outlet liquid | Displays temp. data of two lines of inlet and outlet liquid | ||||
Compresor | Emerson Copeland | ||||
Evaporador | Intercambiador de calor de placas | Intercambiador de calor de placas | |||
Cooling way | Air cooled + Water cooled | Air cooled + Water cooled | |||
Throttle type | Electronic expansion valv | Electronic expansion valv | |||
Filtro seco | Danfoss | ||||
Heating-conduction medium | Synthetic heat conducting oil | ||||
Refrigerante | R404A | R404A | |||
Material de los tubos | SUS304 | SUS304 | |||
Metal insulated hose | 1.8M*4 | 1.8M*4 | |||
Contactor/circuit breaker | Schneider | Schneider | |||
Dimensión cm | 70*100*175 | 70*100*175 | |||
Peso en kg | 325KG | 365KG | |||
Potencia 380V 50HZ | 19kW MAX | 20kW MAX | |||
Material del maletín | Cold rolled steel powder coating (standard color 7035) |
Modelo | WTD-2A38W-2TPEX | WTD-4A38W-2TPEX | WTD-7A50WPEX | |||
Rango de temperatura | -25~200°C | -25~200°C | -45~200°C | -45~200°C | -70~200°C | |
Temp accuracy | ±0.5℃ | |||||
Temp resolution | 0.1K | |||||
Control panel | Pantalla táctil Siemens de 7 pulgadas en color a prueba de explosiones | |||||
Curva de datos | Data Curve Record | |||||
Date output | U disco formato excel | |||||
Sistema de control | Lneya Control System Siemens PLC | |||||
System circulation fluid | 30L+30L | 30L+30L | 50L | |||
Volumen del depósito de expansión | 120L | 120L | 100L | |||
Potencia calorífica | 38 kW | 38 kW | 38 kW | 38 kW | 50 kW | |
Calentador | Electric Heater Heating power 3W/cm2 | |||||
Actuador de calefacción | Voltage regulating actuator 4~20mA control | |||||
Cooling capacity kW | 200°C | 38 kW | 38 kW | 38 kW | 38 kW | 50 kW |
100°C | 38 kW | 38 kW | 38 kW | 38 kW | 50 kW | |
20°C | 38 kW | 38 kW | 38 kW | 38 kW | 50 kW | |
-15°C | 15 kW | 15 kW | 20 kW | 20 kW | 40 kW | |
-35°C | 11 kW | 11 kW | 25 kW | |||
-60°C | 12kW | |||||
Bomba de circulación máx. | 250L/min 3bar | 250L/min 3bar | 250L/min 3bar | 250L/min 3bar | 250L/min 3bar | |
Tamaño de la conexión | DN50 PN16 | |||||
Intercambiador de calor de agua de refrigeración | Intercambiador de calor de doble tubo | |||||
Volumen de agua de refrigeración | 25m³/h 1BAR~4bar max DN65 PN10 | 28m³/h 1BAR~4bar max 接口尺寸DN65 PN10 | 28m³/h1BAR~4bar max DN65 PN10 | |||
Compresor | Emerson copeland scroll flexible compressor | |||||
Temp sensor | PT100 Fluid temperature of each group of inlet and outlet | |||||
Throttle type | Electronic expansion valv | |||||
Filtro seco | Danfoss | |||||
Heating-conduction medium | Aceite sintético para transferencia de calor | |||||
Material de los tubos | SUS304 | |||||
Baja tensión eléctrica | Schneider/Siemens | |||||
Dimensión cm | 250*200*220 | 250*200*220 | 250*200*220 | |||
Peso en kg | 2500KG | 2600KG | 2600KG | |||
Potencia 380V 50HZ | 110kW MAX | 125kW MAX | 120kW MAX | |||
Forma antideflagrante | Positive pressure explosion-proof, Explosion proof product installation license No. PCEC-2017-B025 | |||||
Material del maletín | Cold rolled steel powder coating (standard color 7035) |
WORKING PRINCIPLE

La tecnología de refrigeración de ultra alta temperatura puede enfriar directamente desde una alta temperatura de 300℃[porque sólo el medio de transferencia de calor en la cámara de expansión entra en contacto con el oxígeno en el aire (y la temperatura del tanque de expansión está entre la temperatura normal y 60℃), lo que puede reducir el riesgo de que el medio de transferencia de calor se oxide y absorba agua en el aire. A alta temperatura, ningún medio conductor de calor se evapora, y el control continuo de la temperatura de - 80℃ ~ 190℃, - 70℃ ~ 220℃, - 88℃ ~ 170℃, - 55℃ ~ 250℃ y - 30℃ ~ 300℃ se puede realizar sin presurización.
Color Screen Control

1. Muestra todos los tipos de temperaturas de control del proceso.
2. Muestra el nivel de líquido del medio conductor del calor en el vaso de expansión.
3. Indicación de funcionamiento del sistema de refrigeración.
4. Muestra la indicación de funcionamiento del calentador.
5. Muestra la indicación de funcionamiento de la bomba de circulación.
6. Muestra el control de temp. ( patrón de control de temp. de materiales, control de temp. media conductora de calor ).
7. Se puede ajustar el control del límite superior e inferior de la temperatura.
8. Se puede ajustar la diferencia de temperatura entre la camisa y el material del reactor.
9. Muestra la alarma para añadir el líquido cuando está vacío.
10. El compresor frigorífico puede funcionar de forma manual o automática.
Customized solutions to meet your temperature process needs
CUSTOM CHILLER SIZES
Whether it is portable, compact, large and small chillers, we can custom design them according to your requirements. No matter how many tons of chiller you need, we can create the best solution.
CUSTOM CHILLER TYPES
We provide chillers of various refrigeration types, including but not limited to air-cooled, water-cooled and evaporative-condensing chillers. Regardless of the type of refrigeration compressor, we can design it according to your requirements.
CUSTOM TEMPERATURE RANGES
We can create a custom solution for temperatures from -150℃ to +350℃. Custom temperature ranges for specific industries.
CUSTOM CHILLER VOLTAGE
Customize chiller voltage and phase according to your needs. Optional 110V/60HZ, 220V/60HZ, 380V/50HZ, 220V/50HZ, 400V/50HZ, 460V/60HZ, 440V~480V/60HZ, etc.
Visite la fábrica de LNEYA
Contacto