
SUNDIZ Variable Frequency Series Cooling Heating Systems
APLICACIONES
Compared with SUNDI refrigeration system, the circulation system adopts variable frequency control, which saves more than 20% energy, reduces noise by more than 5 decibels, and has a small starting current compared to old products.
By increasing the frequency, the refrigeration power is increased and the cooling rate is improved by frequency conversion control of the circulation pump.
Características del producto
Parámetros del producto
SUNDIZ -45℃~250℃
Modelo | SUNDIZ4-3 SUNDIZ4-3W |
SUNDIZ4-5 SUNDIZ4-5W |
SUNDIZ4-10 SUNDIZ4-10W |
SUNDIZ4-15W | SUNDIZ4-20W | SUNDIZ4-30W | |
Temperatura | -45℃~250℃ | ||||||
Potencia calorífica | 5,5 kW | 7,5 kW | 15 kW | 25 kW | 38 kW | 60 kW | |
Cooling capacity kW | 250℃ | 5,5 kW | 7,5 kW | 15 kW | 25 kW | 38 kW | 60 kW |
20℃ | 5,5 kW | 7,5 kW | 15 kW | 25 kW | 38 kW | 60 kW | |
-15℃ | 2.3kW | 3.6kW | 7.5 kW | 11 kW | 15 kW | 33kW | |
-35℃ | 0,9 kW | 1,5 kW | 3.3 kW | 5kW | 6,5 kW | 10kW | |
Medium temp control accuracy | ±0.1℃ | ±0.1℃ | ±0.1℃ | ±0.1℃ | ±0.1℃ | ±0.1℃ | |
Process temp control accuracy | ±0.3℃ | ±0.3℃ | ±0.3℃ | ±0.3℃ | ±0.3℃ | ±0.3℃ | |
Pump flow rate pressure max | 50 l/min | 50 l/min | 100L/min | 150L/min | 250 l/min | 400 l/min | |
2bar | 2bar | 2bar | 2,5 bares | 2,5 bares | 2,5 bares | ||
Refrigerante | R-404A / R507C Optional R448 | ||||||
Tamaño de la interfaz | G3/4 | G3/4 | G1 | DN32 PN10 | DN40 PN10 | DN50 PN10 |
SUNDIZ -80℃~250℃
Modelo | SUNDIZ8-3W | SUNDIZ8-4W | SUNDIZ8-6W | SUNDIZ8-10W | SUNDIZ8-15W | |
Temperatura | -80℃~250℃ | |||||
Potencia calorífica | 3,5 kW | 5,5 kW | 7,5 kW | 10kW | 15 kW | |
Cooling capacity kW | 250℃ | 3,5 kW | 5,5 kW | 7,5 kW | 15 kW | 20 kW |
20℃ | 3,5 kW | 5,5 kW | 7.5 kW | 15 kW | 20 kW | |
-60℃ | 1.3kW | 1,8 kW | 3 kW | 5,5 kW | 8kW | |
-75℃ | 0.4kW | 0,6 kW | 1 kW | 1,8 kW | 2.7kW | |
Medium temp control accuracy | ±0.1℃ | ±0.1℃ | ±0.1℃ | ±0.1℃ | ±0.1℃ | |
Process temp control accuracy | ±0.3℃ | ±0.3℃ | ±0.3℃ | ±0.3℃ | ±0.3℃ | |
Pump flow rate pressure max | 35 l/min | 50 l/min | 100L/min | 150L/min | 250 l/min | |
2bar | 2bar | 2bar | 2,5 bares | 2,5 bares | ||
Refrigerante | R-404A / R508B |
Common Configuration
Visualización de la presión del sistema | The pressure of the refrigeration system and circulation system is detected by pressure sensors and displayed on the touch screen | ||||
Controlador | Siemens S7-1200 PLC, fuzzy PID control algorithm, equipped with process dynamic control algorithm | ||||
Control de la temperatura | Thermal medium outlet temperature control mode, external temperature sensor: (PT100 or 4-20mA or communication given) control mode (process dynamic control algorithm) |
||||
Programable | 25 programs, each program can edit 85 steps | ||||
Communication Protocol | Ethernet interface TCP/IP protocol, RS485 interface, MODBUS protocol | ||||
Internal temp feedback | Equipment thermal conductivity medium outlet temperature, medium inlet temperature, refrigeration system condensation temperature, compressor suction temperature, cooling water temperature (for water-cooled equipment) |
||||
External temp feedback | Pt100 or 4-20mA or communication given | ||||
During cascade control Temp difference control function |
The temp difference between the outlet temp of the thermal oil and the external temp sensor can be set and controlled The temp difference between the inlet and outlet of the equipment can be set and controlled to ensure system safety |
||||
Closed circulation sistema |
The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, pressure do not rise up when system is running. The system will supply oil automatically at low temperature. |
||||
Calefacción | Se refiere a la potencia máxima de calefacción del sistema (según cada modelo) El calefactor tiene triple protección y limitador de temperatura independiente para garantizar la seguridad del sistema de calefacción; Using a voltage regulator to control the heating output and reduce the output current of the heater during process temperature control |
||||
External circulation Flow pressure | Brand magnetic drive variable frequency pump | ||||
Compresor | Emerson, Mitsubishi and other variable frequency compressors | ||||
Convertidor de frecuencia | Famous brands such as ABB | ||||
Evaporador | 316L Plate Heat Exchanger | ||||
Accesorios de refrigeración | Danfoss/Emerson accessories (dry filters, oil separators, high and low pressure protectors, expansion valves) | ||||
Panel de control | LNEYA pantalla táctil en color de 7 pulgadas personalizada, visualización de la curva de temperatura\EXCEL exportación de datos | ||||
Protección de seguridad | Multiple self-diagnosis function; freezer overload protection; high/low pressure switch; overload relay, thermal protection device etc | ||||
Water-cooled condenser | Intercambiador de calor de placas | ||||
Material de la carcasa | Cold rolled sheet (standard color 7035) | ||||
Potencia | 380V 50HZ / 460V 60HZ |
WORKING PRINCIPLE

La tecnología de refrigeración de ultra alta temperatura puede enfriar directamente desde una alta temperatura de 300℃[porque sólo el medio de transferencia de calor en la cámara de expansión entra en contacto con el oxígeno en el aire (y la temperatura del tanque de expansión está entre la temperatura normal y 60℃), lo que puede reducir el riesgo de que el medio de transferencia de calor se oxide y absorba agua en el aire. A alta temperatura, ningún medio conductor de calor se evapora, y el control continuo de la temperatura de - 80℃ ~ 190℃, - 70℃ ~ 220℃, - 88℃ ~ 170℃, - 55℃ ~ 250℃ y - 30℃ ~ 300℃ se puede realizar sin presurización.
Color Screen Control

1. Muestra todos los tipos de temperaturas de control del proceso.
2. Muestra el nivel de líquido del medio conductor del calor en el vaso de expansión.
3. Indicación de funcionamiento del sistema de refrigeración.
4. Muestra la indicación de funcionamiento del calentador.
5. Muestra la indicación de funcionamiento de la bomba de circulación.
6. Muestra el control de temp. ( patrón de control de temp. de materiales, control de temp. media conductora de calor ).
7. Se puede ajustar el control del límite superior e inferior de la temperatura.
8. Se puede ajustar la diferencia de temperatura entre la camisa y el material del reactor.
9. Muestra la alarma para añadir el líquido cuando está vacío.
10. El compresor frigorífico puede funcionar de forma manual o automática.
Customized solutions to meet your temperature process needs
CUSTOM CHILLER SIZES
Whether it is portable, compact, large and small chillers, we can custom design them according to your requirements. No matter how many tons of chiller you need, we can create the best solution.
CUSTOM CHILLER TYPES
We provide chillers of various refrigeration types, including but not limited to air-cooled, water-cooled and evaporative-condensing chillers. Regardless of the type of refrigeration compressor, we can design it according to your requirements.
CUSTOM TEMPERATURE RANGES
We can create a custom solution for temperatures from -150℃ to +350℃. Custom temperature ranges for specific industries.
CUSTOM CHILLER VOLTAGE
Customize chiller voltage and phase according to your needs. Optional 110V/60HZ, 220V/60HZ, 380V/50HZ, 220V/50HZ, 400V/50HZ, 460V/60HZ, 440V~480V/60HZ, etc.
¿Por qué elegir lneya como proveedor de control de temperatura?
Años de experiencia
Clientes satisfechos
m² Área de producción
Tecnologías patentadas
Visite la fábrica de LNEYA
Contacto
Envíenos su solicitud y nos pondremos en contacto con usted en 24 horas