SUNDI series Chiller and Heater Combo Units
APLICACIONES
Dynamic constant temperature control of cold and hot sources of high-pressure reactors;
Dynamic constant temperature control of cold and hot sources of double-layer glass reactors;
Dynamic constant temperature control of cold and hot sources of double-layer reactors;
Constant temperature control of cold and hot sources of microchannel reactors;
Small constant temperature control systems, distillation system temperature control;
Low-temperature and high-temperature aging tests of materials;
Constant temperature control of combined chemical cold and hot sources;
Cooling and heating of semiconductor equipment;
Constant temperature control of refrigeration and heating of vacuum chambers.
Características del producto
Parámetros del producto
Modelo | SUNDI-320 SUNDI-320W | |
Rango de temperatura | -30℃~180℃ | |
Precisión a media temperatura | ±0.5℃ | |
Precisión de la temperatura del material |
±1℃ |
|
Potencia calorífica | 2kW | |
Refrigeración capacidad |
180℃ | 1,5 kW |
50℃ | 1,5 kW | |
0℃ | 1,5 kW | |
-5℃ | 0.7kW | |
-15℃ | 0.4kW | |
Flow、pressure | max10L/min 0,8bar |
|
Refrigerante | R-404A/R507C | |
Tamaño de la conexión | ZG1/2 | |
Dimensión cm | 35*56*75 | |
Peso en kg | 55 kg | |
Potencia | AC 220V 50HZ 3.2kW(max) |
Modelo | SUNDI-135 SUNDI-135W |
SUNDI-155 SUNDI-155W |
SUNDI-175 SUNDI-175W |
SUNDI-1A10 SUNDI-1A10W |
SUNDI-1A15 SUNDI-1A15W |
|
Rango de temperatura | -10℃~+150℃ | |||||
Modo de control | Retroalimentación PID + Nuestro cálculo especial de control dinámico, controlador PLC | |||||
Temp control | Modelo de control de temp. de proceso y temp. de camisa | |||||
Temp difference | Ajustar o controlar la diferencia de temperatura entre el aceite de la camisa y el proceso de la materia prima | |||||
Editor de programas | 20 programs, each program can edit 40 steps | |||||
Communication Protoco | Protocolo MODBUS RTU, interfaz RS485 | |||||
Material temp feedback | PT100 | |||||
Información sobre la temperatura | The temp of 3 points: the inlet and outlet of equipment,reactor material temperature(external temp. sensor) | |||||
Precisión a media temperatura | ±0.5℃ | |||||
Precisión de la temperatura del material | ±1℃ | |||||
Potencia calorífica | 3.5 | 5.5 | 7.5 | 10 | 15 | |
Refrigeración capacidad |
150℃ | 3.5 | 5.5 | 7.5 | 10 | 15 |
20℃ | 3.5 | 5.5 | 7.5 | 10 | 15 | |
-5℃ | 2.1 | 3.3 | 4.2 | 6 | 9 | |
Flow、pressure max L/min bar |
35 | 35 | 50 | 50 | 75 | |
1 | 1 | 1.2 | 1.2 | 1.2 | ||
Compresor | Highly / Panasonic / Emerson copeland / scroll compressor | |||||
Válvula de expansión | Válvula de expansión electrónica | |||||
Evaporador | Intercambiador de placas | |||||
Panel de control | Pantalla táctil de 7 pulgadas, muestra la curva de temperatura, salida de datos EXCEL. | |||||
Protección de seguridad | Self-diagnosis function; freezer overload protection; high pressure switch, overload relay,thermal protection device, high temperature protection and temperature fault protection. |
|||||
Sistema de circulación cerrado | Todo el sistema es de circulación cerrada, no hay neblina de aceite a alta temperatura y no hay vapor de agua a baja temperatura, la presión no se eleva cuando el sistema está funcionando. El sistema suministrará aceite automáticamente a baja temperatura. | |||||
Refrigerante | R-404A/R507C | |||||
Tamaño de la conexión | ZG3/4 | ZG3/4 | ZG1 | ZG1 | ZG1 | |
Agua de refrigeración @20℃ |
1300L/H 1,5bar~4bar ZG1/2 |
1800L/H 1,5bar~4bar ZG3/4 |
1800L/H 1,5bar~4bar ZG3/4 |
2400L/H 1,5bar~4bar ZG3/4 |
3600L/H 1,5bar~4bar ZG1 |
|
Dimensión cm | 45*70*160 | 45*70*160 | 55*70*175 | 55*70*175 | 70*85*185 | |
Peso en kg | 165 | 185 | 235 | 280 | 300 | |
Potencia 380V 50HZ | 6.7kW | 9,5 kW | 12kW | 15.5kW | 23 kW | |
Case materia | Cold rolled steel powder coating (standard color 7035) | |||||
Opcional | Optional Ethernet interface and computer operation software configuration | |||||
Opcional | Outside touch screen display controller, the communication line distance is 10 meter |
|||||
OptionalPower | 110V 50HZ single-phase, 110V 60HZ single-phase, 230V 60HZ single-phase, 220V 60HZ 3-phase, 440V~460V 60HZ 3-phase |
Modelo | SUNDI-235 SUNDI-235W |
SUNDI-255 SUNDI-255W |
SUNDI-275 SUNDI-275W |
SUNDI-2A10 SUNDI-2A10W |
SUNDI-2A15 SUNDI-2A15W |
SUNDI-2A25 SUNDI-2A25W |
SUNDI-2A38W | SUNDI-2A60W | SUNDI-2A95W | SUNDI-2A130W | SUNDI-2A200W | |
Rango de temperatura | -25℃~+200℃(can be -25℃~+300℃) | |||||||||||
Modo de control | Retroalimentación PID + Nuestro cálculo especial de control dinámico, controlador PLC | |||||||||||
Temp control | Modelo de control de temp. de proceso y temp. de camisa | |||||||||||
Temp difference | Ajustar o controlar la diferencia de temperatura entre el aceite de la camisa y el proceso de la materia prima | |||||||||||
Editor de programas | 20 programs, each program can edit 40 steps | |||||||||||
Communication Protoco | Protocolo MODBUS RTU, interfaz RS485 | |||||||||||
Material temp feedback | PT100 | |||||||||||
Información sobre la temperatura | The temp of 3 points: the inlet and outlet of equipment,reactor material temperature(external temp. sensor) | |||||||||||
Precisión a media temperatura | ±0.5℃ | |||||||||||
Precisión de la temperatura del material | ±1℃ | |||||||||||
Potencia calorífica | 3.5 | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | 95 | 130 | 200 | |
Refrigeración capacidad |
200℃ | 3.5 | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | 95 | 130 | 200 |
100℃ | 3.5 | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | 95 | 130 | 200 | |
50℃ | 3.5 | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | 95 | 130 | 200 | |
20℃ | 3.5 | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | 95 | 130 | 200 | |
-5℃ | 3 | 4.5 | 6.3 | 8 | 11 | 19 | 30 | 46 | 70 | 80 | 125 | |
-15℃ | 1.8 | 2.8 | 3.8 | 4.6 | 7 | 12 | 16 | 22 | 32 | 43 | 65 | |
Flow、pressure max L/min bar |
35 | 35 | 50 | 60 | 110 | 150 | 200 | 250 | 400 | 400 | 600 | |
1.2 | 1.2 | 1.2 | 1.2 | 1.5 | 1.5 | 1.5 | 2.5 | 2.5 | 2.5 | 2.5 | ||
Compresor | Tecumseh Emerson copeland / Carlyle | |||||||||||
Válvula de expansión | Válvula de expansión electrónica | |||||||||||
Evaporador | Intercambiador de placas | |||||||||||
Panel de control | Pantalla táctil de 7 pulgadas, muestra la curva de temperatura, salida de datos EXCEL. | |||||||||||
Protección de seguridad | Self-diagnosis function; freezer overload protection; high pressure switch, overload relay,thermal protection device, high temperature protection and temperature fault protection. |
|||||||||||
Sistema de circulación cerrado | Todo el sistema es de circulación cerrada, no hay neblina de aceite a alta temperatura y no hay vapor de agua a baja temperatura, la presión no se eleva cuando el sistema está funcionando. El sistema suministrará aceite automáticamente a baja temperatura. | |||||||||||
Refrigerante | R-404A/R507C | |||||||||||
Tamaño de la conexión | ZG3/4 | ZG3/4 | ZG1 | ZG1 | ZG1 | DN32 | DN40 | DN50 | DN65 | DN65 | DN80 | |
Agua de refrigeración @20℃ |
1500L/H 1,5bar~4bar ZG1/2 |
1800L/H 1,5bar~4bar ZG3/4 |
3000L/H 1,5bar~4bar ZG3/4 |
4200L/H 1,5bar~4bar ZG3/4 |
5400L/H 1,5bar~4bar DN32 |
10 m³/H 1,5bar~4bar DN40 |
10 m³/H 1,5bar~4bar DN40 |
14 m³/H 1,5bar~4bar DN50 |
19m³/H 1,5bar~4bar DN65 |
24m³/H 1,5bar~4bar DN65 |
36m³/H 1,5bar~4bar DN80 |
|
Dimensión cm | 45*70*160 | 45*70*160 | 55*70*175 | 65*85*185 | 70*85*185 | 80*120*185 | 150*100*185 | 200*145*205 | 200*145*205 | 250*145*225 | 300*160*225 | |
Peso en kg | 165 | 185 | 230 | 280 | 300 | 550 | 750 | 1000 | 1250 | 1580 | 2150 | |
Potencia 380V 50HZ | 6.7kW | 9,5 kW | 15 kW | 16 kW | 27 kW | 48 kW | 55 kW | 81kW | 126kW | 175kW | 260 kW | |
Case materia | Cold rolled steel powder coating (standard color 7035) | |||||||||||
Opcional | Optional Ethernet interface and computer operation software configuration | |||||||||||
Opcional | Outside touch screen display controller, the communication line distance is 10 meter |
|||||||||||
OptionalPower | 110V 50HZ single-phase, 110V 60HZ single-phase, 230V 60HZ single-phase, 220V 60HZ 3-phase, 440V~460V 60HZ 3-phase | |||||||||||
Opcional | SUNDI series can provide optional medium temperature control accuracy of ± 0.1 ℃ and material temperature control accuracy of ± 0.1 ℃ within a heating power of 25kW |
Modelo | SUNDI-525 SUNDI-525W |
SUNDI-535 SUNDI-535W |
SUNDI-555 SUNDI-555W |
SUNDI-575 SUNDI-575W |
SUNDI-5A10 SUNDI-5A10W |
SUNDI-5A15 SUNDI-5A15W |
SUNDI-4A25 SUNDI-4A25W |
SUNDI-4A38W | SUNDI-4A60W | SUNDI-4A95W | SUNDI-4A130W | SUNDI-4A200W | |
Rango de temperatura | -45℃~+250℃ | ||||||||||||
Modo de control | Retroalimentación PID + Nuestro cálculo especial de control dinámico, controlador PLC | ||||||||||||
Temp control | Modelo de control de temp. de proceso y temp. de camisa | ||||||||||||
Temp difference | Ajustar o controlar la diferencia de temperatura entre el aceite de la camisa y el proceso de la materia prima | ||||||||||||
Editor de programas | 20 programs, each program can edit 40 steps | ||||||||||||
Communication Protoco | Protocolo MODBUS RTU, interfaz RS485 | ||||||||||||
Material temp feedback | PT100 | ||||||||||||
Información sobre la temperatura | The temp of 3 points: the inlet and outlet of equipment,reactor material temperature(external temp. sensor) | ||||||||||||
Precisión a media temperatura | ±0.5℃ | ||||||||||||
Precisión de la temperatura del material | ±1℃ | ||||||||||||
Potencia calorífica | 2.5 | 3.5 | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | 95 | 130 | 200 | |
Capacidad de refrigeración | 250℃ | 2.5 | 3.5 | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | 95 | 130 | 200 |
100℃ | 2.5 | 3.5 | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | 95 | 130 | 200 | |
20℃ | 2.5 | 3.5 | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | 95 | 130 | 200 | |
0℃ | 1.8 | 3 | 5 | 7 | 10 | 15 | 25 | 38 | 60 | 95 | 130 | 200 | |
-20℃ | 0.85 | 1.5 | 2.3 | 3.6 | 5 | 7.6 | 11 | 20 | 29 | 42 | 54 | 98 | |
-35℃ | 0.25 | 0.45 | 0.9 | 1.5 | 2 | 3.8 | 4.7 | 9 | 12 | 18 | 24 | 43 | |
Caudal、presión máx L/min bar | 20 | 35 | 35 | 50 | 60 | 110 | 150 | 200 | 250 | 400 | 400 | 600 | |
1.2 | 1.2 | 1.2 | 1.2 | 1.5 | 1.5 | 1.5 | 1.5 | 2.5 | 2.5 | 2.5 | 2.5 | ||
Bomba de circulación | Bomba de accionamiento magnético | ||||||||||||
Compresor | Tecumseh/Emerson copeland/Carlyle | ||||||||||||
Válvula de expansión | Válvula de expansión electrónica | ||||||||||||
Evaporador | Intercambiador de placas | ||||||||||||
Panel de control | Pantalla táctil de 7 pulgadas, muestra la curva de temperatura, salida de datos EXCEL. | ||||||||||||
Protección de seguridad | Self-diagnosis function; freezer overload protection; high pressure switch, overload relay,thermal protection device, high temperature protection and temperature fault protection. |
||||||||||||
Sistema de circulación cerrado | Todo el sistema es de circulación cerrada, no hay neblina de aceite a alta temperatura y no hay vapor de agua a baja temperatura, la presión no se eleva cuando el sistema está funcionando. El sistema suministrará aceite automáticamente a baja temperatura. | ||||||||||||
Refrigerante | R-404A/R507C | ||||||||||||
Tamaño de la conexión | ZG1/2 | ZG3/4 | ZG3/4 | ZG3/4 | ZG1 | ZG1 | DN32 | DN50 | DN50 | DN65 | DN65 | DN65 | |
Agua de refrigeración @20℃ |
900L/H 1,5bar~4bar ZG1/2 |
1400L/H 1,5bar~4bar ZG1/2 |
1800L/H 1,5bar~4bar ZG3/4 |
2400L/H 1,5bar~4bar ZG3/4 |
3600L/H 1,5bar~4bar ZG1 |
4800L/H 1,5bar~4bar ZG1 |
9 m³/H 1,5bar~4bar DN40 |
10 m³/H 1,5bar~4bar DN50 |
15 m³/H 1,5bar~4bar DN50 |
20 m³/H 1,5bar~4bar DN65 |
32 m³/H 1,5bar~4bar DN80 |
46 m³/H 1,5bar~4bar DN100 |
|
Dimensión cm | 45*70*160 | 45*70*160 | 55*70*175 | 55*70*175 | 65*85*185 | 70*85*185 | 80*120*185 | 150*100*185 | 200*145*205 | 200*145*205 | 250*145*225 | 300*160*225 | |
Peso en kg | 160 | 180 | 195 | 260 | 320 | 390 | 620 | 820 | 1100 | 1350 | 1680 | 2250 | |
Potencia 380V 50hz | AC220V 4kW | 7kW | 9kW | 13kW | 16 kW | 26 kW | 42kW | 57 kW | 82 kW | 136 kW | 183 kW | 309 kW | |
Case materia | Cold rolled steel powder coating (standard color 7035) | ||||||||||||
Opcional | Optional Ethernet interface and computer operation software configuration | ||||||||||||
Opcional | Outside touch screen display controller, the communication line distance is 10 meter |
||||||||||||
OptionalPower | 110V 50HZ single-phase, 110V 60HZ single-phase, 230V 60HZ single-phase, 220V 60HZ 3-phase, 440V~460V 60HZ 3-phase | ||||||||||||
Opcional | SUNDI series can provide optional medium temperature control accuracy of ± 0.1 ℃ and material temperature control accuracy of ± 0.1 ℃ within a heating power of 25kW |
Modelo | SUNDI-625 SUNDI-625W |
SUNDI-635 SUNDI-635W |
SUNDI-655 SUNDI-655W |
SUNDI-675 SUNDI-675W |
SUNDI-6A10 SUNDI-6A10W |
SUNDI-6A15W | SUNDI-6A25W | SUNDI-6A38W | SUNDI-6A60W | |
Rango de temperatura | -60℃~+250℃ | |||||||||
Modo de control | Retroalimentación PID + Nuestro cálculo especial de control dinámico, controlador PLC | |||||||||
Temp control | Modelo de control de temp. de proceso y temp. de camisa | |||||||||
Temp difference | Ajustar o controlar la diferencia de temperatura entre el aceite de la camisa y el proceso de la materia prima | |||||||||
Editor de programas | 20 programs, each program can edit 40 steps | |||||||||
Communication Protoco | Protocolo MODBUS RTU, interfaz RS485 | |||||||||
Material temp feedback | PT100 | |||||||||
Información sobre la temperatura | The temp of 3 points: the inlet and outlet of equipment,reactor material temperature(external temp. sensor) | |||||||||
Precisión a media temperatura | ±0.5℃ | |||||||||
Precisión de la temperatura del material | ±1℃ | |||||||||
Potencia calorífica | 2.5 | 3.5 | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | |
Capacidad de refrigeración | 250℃ | 2.5 | 3.5 | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 |
100℃ | 2.5 | 3.5 | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | |
20℃ | 2.5 | 3.5 | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | |
-40℃ | 0.95 | 1.45 | 2.3 | 3.1 | 4.8 | 7.8 | 18 | 23 | 31 | |
-55℃ | 0.25 | 0.5 | 0.75 | 0.9 | 1.5 | 2.8 | 6 | 8 | 11 | |
Flow、pressuremax L/min bar | 20 | 35 | 35 | 50 | 60 | 110 | 150 | 200 | 250 | |
1.2 | 1.2 | 1.2 | 1.2 | 1.5 | 1.5 | 1.5 | 1.5 | 2.5 | ||
Bomba de circulación | Bomba de accionamiento magnético | |||||||||
Compresor | Tecumseh/Emerson copeland/Carlyle | |||||||||
Válvula de expansión | Válvula de expansión electrónica | |||||||||
Evaporador | Intercambiador de placas | |||||||||
Panel de control | Pantalla táctil de 7 pulgadas, muestra la curva de temperatura, salida de datos EXCEL. | |||||||||
Protección de seguridad | Self-diagnosis function; freezer overload protection; high pressure switch, overload relay,thermal protection device, high temperature protection and temperature fault protection. |
|||||||||
Sistema de circulación cerrado | Todo el sistema es de circulación cerrada, no hay neblina de aceite a alta temperatura y no hay vapor de agua a baja temperatura, la presión no se eleva cuando el sistema está funcionando. El sistema suministrará aceite automáticamente a baja temperatura. | |||||||||
Refrigerante | R-404A/R23 | |||||||||
Tamaño de la conexión | ZG1/2 | ZG3/4 | ZG3/4 | ZG1 | ZG1 | ZG1 | DN32 | DN40 | DN50 | |
Agua de refrigeración @20℃ |
1100L/H 1,5bar~4bar ZG1/2 |
2000L/H 1,5bar~4bar ZG3/4 |
2300L/H 1,5bar~4bar ZG3/4 |
2600L/H 1,5bar~4bar ZG3/4 |
3300L/H 1,5bar~4bar ZG1 |
4000L/H 1,5bar~4bar ZG1 1/4 |
8,5 m³/H 1,5bar~4bar DN40 |
14 m³/H 1,5bar~4bar DN50 |
20 m³/H 1,5bar~4bar DN65 |
|
Dimensión cm | 55*70*175 | 55*70*175 | 55*70*175 | 65*85*185 | 65*85*185 | 80*120*185 | 150*100*185 | 200*145*205 | 200*145*205 | |
Peso en kg | 205 | 225 | 300 | 340 | 380 | 380 | 980 | 1350 | 1580 | |
Potencia 380V 50HZ | 5kW | 10kW | 12kW | 18 kW | 22kW | 28 kW | 56kW | 73 kW | 110kW | |
Case materia | Cold rolled steel powder coating (standard color 7035) | |||||||||
Opcional | Optional Ethernet interface and computer operation software configuration | |||||||||
Opcional | Outside touch screen display controller, the communication line distance is 10 meter |
|||||||||
OptionalPower | 110V 50HZ single-phase, 110V 60HZ single-phase, 230V 60HZ single-phase, 220V 60HZ 3-phase, 440V~460V 60HZ 3-phase | |||||||||
Opcional | SUNDI series can provide optional medium temperature control accuracy of ± 0.1 ℃ and material temperature control accuracy of ± 0.1 ℃ within a heating power of 25kW |
Modelo | SUNDI-825W | SUNDI-835W | SUNDI-855W | SUNDI-875W | SUNDI-8A10W | SUNDI-8A15W | SUNDI-8A25W | SUNDI-8A38W | SUNDI-8A60W | SUNDI-8A80W | |
Rango de temperatura | -80℃~+250℃ | ||||||||||
Modo de control | Retroalimentación PID + Nuestro cálculo especial de control dinámico, controlador PLC | ||||||||||
Temp control | El control de la temperatura del material y el modo de control de la temperatura de salida del equipo pueden seleccionarse libremente | ||||||||||
Temp difference | Ajustar o controlar la diferencia de temperatura entre el aceite de la camisa y el proceso de la materia prima | ||||||||||
Editor de programas | 20 programs, each program can edit 40 steps | ||||||||||
Communication Protoco | Protocolo MODBUS RTU, interfaz RS485 | ||||||||||
Material temp feedback | PT100 | ||||||||||
Información sobre la temperatura | The temp of 3 points: the inlet and outlet of equipment,reactor material temperature(external temp. sensor) | ||||||||||
Precisión a media temperatura | ±0.5℃ | ||||||||||
Precisión de la temperatura del material | ±1℃ | ||||||||||
Potencia calorífica | 3 | 3.5 | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | 80 | |
Capacidad de refrigeración | 250℃ | 2.5 | 3.5 | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | 80 |
20℃ | 2.5 | 3.5 | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | 80 | |
-60℃ | 1 | 1.4 | 1.6 | 3 | 3.5 | 5.8 | 10 | 16 | 23 | 32 | |
-75℃ | 0.3 | 0.42 | 0.7 | 1.3 | 1.5 | 2.4 | 5 | 8 | 11 | 16 | |
Flow、pressuremax L/min bar |
20 | 35 | 35 | 50 | 60 | 110 | 150 | 250 | 400 | 400 | |
1.2 | 1.2 | 1.2 | 1.2 | 1.5 | 1.5 | 1.5 | 1.5 | 2.5 | 2.5 | ||
Bomba de circulación | Bomba de accionamiento magnético | ||||||||||
Compresor | Emerson copeland/Carlyle | ||||||||||
Válvula de expansión | Válvula de expansión electrónica | ||||||||||
Evaporador | Intercambiador de placas | ||||||||||
Panel de control | Pantalla táctil de 7 pulgadas, muestra la curva de temperatura, salida de datos EXCEL. | ||||||||||
Protección de seguridad | Self-diagnosis function; freezer overload protection; high pressure switch, overload relay,thermal protection device, high temperature protection and temperature fault protection. |
||||||||||
Sistema de circulación cerrado | Todo el sistema es de circulación cerrada, no hay neblina de aceite a alta temperatura y no hay vapor de agua a baja temperatura, la presión no se eleva cuando el sistema está funcionando. El sistema suministrará aceite automáticamente a baja temperatura. | ||||||||||
Refrigerante | R-404A/R508B | ||||||||||
Tamaño de la conexión | ZG1/2 | ZG3/4 | ZG3/4 | ZG1 | ZG1 | ZG1 | DN32 | DN40 | DN65 | DN65 | |
Agua de refrigeración @20℃ |
1800L/H 1,5bar~4bar ZG3/4 |
2000L/H 1,5bar~4bar ZG3/4 |
2800L/H 1,5bar~4bar ZG3/4 |
3500L/H 1,5bar~4bar ZG1 |
4200L/H 1,5bar~4bar ZG1 |
5600L/H 1,5bar~4bar DN32 |
10 m³/H 1,5bar~4bar DN40 |
18 m³/H 1,5bar~4bar DN65 |
28 m³/H 1,5bar~4bar DN80 |
30 m³/H 1,5bar~4bar DN80 |
|
Dimensión cm | 55*70*175 | 55*70*175 | 65*85*185 | 70*85*185 | 70*85*185 | 80*120*185 | 150*100*185 | 200*145*205 | 245*170*225 | 300*160*225 | |
Peso en kg | 240 | 285 | 345 | 500 | 600 | 950 | 1300 | 1550 | 2200 | 2850 | |
Potencia 380V 50HZ | 9,5 kW | 11 kW | 17 kW | 20 kW | 26 kW | 36 kW | 59kW | 98kW | 135kW | 177 kW | |
Case materia | Cold rolled steel powder coating (standard color 7035) | ||||||||||
Opcional | Optional Ethernet interface and computer operation software configuration | ||||||||||
Opcional | Outside touch screen display controller, the communication line distance is 10 meter |
||||||||||
OptionalPower | 110V 50HZ single-phase, 110V 60HZ single-phase, 230V 60HZ single-phase, 220V 60HZ 3-phase, 440V~460V 60HZ 3-phase | ||||||||||
Opcional | SUNDI series can provide optional medium temperature control accuracy of ± 0.1 ℃ and material temperature control accuracy of ± 0.1 ℃ within a heating power of 25kW |
Modelo | SUNDI-955W | SUNDI-975W | SUNDI-9A10W | SUNDI-9A15W | SUNDI-9A25W | SUNDI-9A38W | SUNDI-9A60W | SUNDI-9A80W | |
Rango de temperatura | -90℃~+250℃ | ||||||||
Modo de control | Retroalimentación PID + Nuestro cálculo especial de control dinámico, controlador PLC | ||||||||
Temp control | Modelo de control de temp. de proceso y temp. de camisa | ||||||||
Temp difference | Ajustar o controlar la diferencia de temperatura entre el aceite de la camisa y el proceso de la materia prima | ||||||||
Editor de programas | 20 programs, each program can edit 40 steps | ||||||||
Communication Protoco | Protocolo MODBUS RTU, interfaz RS485 | ||||||||
Material temp feedback | PT100 | ||||||||
Información sobre la temperatura | The temp of 3 points: the inlet and outlet of equipment,reactor material temperature(external temp. sensor) | ||||||||
Precisión a media temperatura | ±0.5℃ | ||||||||
Precisión de la temperatura del material | ±1℃ | ||||||||
Potencia calorífica | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | 80 | |
Capacidad de refrigeración | 250℃ | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | 80 |
0℃ | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | 80 | |
-60℃ | 2.8 | 3.2 | 4.2 | 6 | 10 | 16 | 24 | 32 | |
-80℃ | 0.8 | 1.2 | 1.6 | 2.1 | 3.5 | 6 | 11 | 15 | |
-85℃ | 0.5 | 0.7 | 0.85 | 1.3 | 1.9 | 3.5 | 6 | 8 | |
Flow、pressure max L/min bar |
35 | 50 | 60 | 110 | 150 | 250 | 400 | 400 | |
1.2 | 1.2 | 1.5 | 1.5 | 1.5 | 1.5 | 2.5 | 2.5 | ||
Bomba de circulación | Bomba de accionamiento magnético | ||||||||
Compresor | Emerson copeland/Carlyle | ||||||||
Válvula de expansión | Válvula de expansión electrónica | ||||||||
Evaporador | Intercambiador de placas | ||||||||
Panel de control | Pantalla táctil de 7 pulgadas, muestra la curva de temperatura, salida de datos EXCEL. | ||||||||
Protección de seguridad | Self-diagnosis function; freezer overload protection; high pressure switch, overload relay,thermal protection device, high temperature protection and temperature fault protection. |
||||||||
Sistema de circulación cerrado | Todo el sistema es de circulación cerrada, no hay neblina de aceite a alta temperatura y no hay vapor de agua a baja temperatura, la presión no se eleva cuando el sistema está funcionando. El sistema suministrará aceite automáticamente a baja temperatura. | ||||||||
Refrigerante | R-404A/R508B | ||||||||
Tamaño de la conexión | ZG3/4 | ZG1 | ZG1 | ZG1 | DN32 PN10 | DN40 PN10 | DN65 PN10 | DN65 PN10 | |
Agua de refrigeración @20℃ |
3400L/H 1,5bar~4bar ZG1 |
4500L/H 1,5bar~4bar ZG1 |
5200L/H 1,5bar~4bar ZG1 1/4 |
8 m³/H 1,5bar~4bar DN40 |
12 m³/H 1,5bar~4bar DN50 |
20 m³/H 1,5bar~4bar DN65 |
30 m³/H 1,5bar~4bar DN80 |
40 m³/H 1,5bar~4bar DN100 |
|
Dimensión cm | 80*120*185 | 80*120*185 | 80*120*185 | 150*100*185 | 200*145*205 | 200*145*205 | 250*160*225 | 300*160*225 | |
Peso en kg | 365 | 570 | 680 | 950 | 1400 | 1750 | 2400 | 3150 | |
Potencia 380V 50HZ | 16 kW | 27 kW | 30 kW | 42kW | 59kW | 83kW | 130 kW | 188kW | |
Case materia | Cold rolled steel powder coating (standard color 7035) | ||||||||
Opcional | Optional Ethernet interface and computer operation software configuration | ||||||||
Opcional | Outside touch screen display controller, the communication line distance is 10 meter |
||||||||
OptionalPower | 110V 50HZ single-phase, 110V 60HZ single-phase, 230V 60HZ single-phase, 220V 60HZ 3-phase, 440V~460V 60HZ 3-phase | ||||||||
Opcional | SUNDI series can provide optional medium temperature control accuracy of ± 0.1 ℃ and material temperature control accuracy of ± 0.1 ℃ within a heating power of 25kW |
Modelo | SUNDI-1055W | SUNDI-1075W | SUNDI-10A10W | SUNDI-10A15W | SUNDI-10A25W | SUNDI-10A38W | SUNDI-10A60W | SUNDI-10A80W | |
Rango de temperatura | -100℃~+100℃ | ||||||||
Modo de control | Retroalimentación PID + Nuestro cálculo especial de control dinámico, controlador PLC | ||||||||
Temp control | Modelo de control de temp. de proceso y temp. de camisa | ||||||||
Temp difference | Ajustar o controlar la diferencia de temperatura entre el aceite de la camisa y el proceso de la materia prima | ||||||||
Editor de programas | 20 programs, each program can edit 40 steps | ||||||||
Communication Protoco | Protocolo MODBUS RTU, interfaz RS485 | ||||||||
Material temp feedback | PT100 | ||||||||
Información sobre la temperatura | The temp of 3 points: the inlet and outlet of equipment,reactor material temperature(external temp. sensor) | ||||||||
Precisión a media temperatura | ±0.5℃ | ||||||||
Precisión de la temperatura del material | ±1℃ | ||||||||
Potencia calorífica | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | 80 | |
Capacidad de refrigeración | 100℃ | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | 80 |
0℃ | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | 80 | |
-80℃ | 2.8 | 3.4 | 4.1 | 5 | 8 | 13 | 22 | 30 | |
-90℃ | 1.2 | 1.6 | 2 | 3 | 4.8 | 7.5 | 12 | 16 | |
-95℃ | 0.7 | 0.9 | 1.2 | 1.8 | 2.9 | 4.5 | 7.2 | 9.5 | |
Flow、pressure max L/min bar |
35 | 50 | 60 | 110 | 150 | 250 | 400 | 400 | |
1.2 | 1.2 | 1.5 | 1.5 | 1.5 | 1.5 | 2.5 | 2.5 | ||
Bomba de circulación | Bomba de accionamiento magnético | ||||||||
Compresor | Emerson copeland/Carlyle | ||||||||
Válvula de expansión | Válvula de expansión electrónica | ||||||||
Evaporador | Intercambiador de placas | ||||||||
Panel de control | Pantalla táctil de 7 pulgadas, muestra la curva de temperatura, salida de datos EXCEL. | ||||||||
Protección de seguridad | Self-diagnosis function; freezer overload protection; high pressure switch, overload relay,thermal protection device, high temperature protection and temperature fault protection. |
||||||||
Sistema de circulación cerrado | Todo el sistema es de circulación cerrada, no hay neblina de aceite a alta temperatura y no hay vapor de agua a baja temperatura, la presión no se eleva cuando el sistema está funcionando. El sistema suministrará aceite automáticamente a baja temperatura. | ||||||||
Refrigerante | R-404A/R23/R14 | ||||||||
Tamaño de la conexión | ZG3/4 | ZG1 | ZG1 | DN32 | DN32 | DN40 | DN65 | DN65 | |
Agua de refrigeración @20℃ |
5000L/H 1.5~4bar ZG1 1/4 |
7000L/H 1.5~4bar DN40 |
9000L/H 1.5~4bar DN40 |
12 m³/H 1.5~4bar DN50 |
20 m³/H 1.5~4bar DN65 |
25 m³/H 1.5~4bar DN65 |
40 m³/H 1.5~4bar DN80 |
50 m³/H 1.5~4bar DN100 |
|
Dimensión cm | 80*120*185 | 150*100*185 | 150*100*185 | 200*145*205 | 200*145*205 | 250*160*225 | 300*160*225 | 400*160*225 | |
Peso en kg | 565 | 705 | 890 | 1250 | 1600 | 2100 | 2950 | 3350 | |
Potencia 380V 50HZ | 26W | 28 kW | 37 kW | 49 kW | 69 kW | 82 kW | 170 kW | 200 kW | |
Case materia | Cold rolled steel powder coating (standard color 7035) | ||||||||
Opcional | Optional Ethernet interface and computer operation software configuration | ||||||||
Opcional | Outside touch screen display controller, the communication line distance is 10 meter |
||||||||
Potencia opcional | 110V 50HZ single-phase, 110V 60HZ single-phase, 230V 60HZ single-phase, 220V 60HZ 3-phase, 440V~460V 60HZ 3-phase | ||||||||
Opcional | SUNDI series can provide optional medium temperature control accuracy of ± 0.1 ℃ and material temperature control accuracy of ± 0.1 ℃ within a heating power of 25kW |
WORKING PRINCIPLE

La tecnología de refrigeración de ultra alta temperatura puede enfriar directamente desde una alta temperatura de 300℃[porque sólo el medio de transferencia de calor en la cámara de expansión entra en contacto con el oxígeno en el aire (y la temperatura del tanque de expansión está entre la temperatura normal y 60℃), lo que puede reducir el riesgo de que el medio de transferencia de calor se oxide y absorba agua en el aire. A alta temperatura, ningún medio conductor de calor se evapora, y el control continuo de la temperatura de - 80℃ ~ 190℃, - 70℃ ~ 220℃, - 88℃ ~ 170℃, - 55℃ ~ 250℃ y - 30℃ ~ 300℃ se puede realizar sin presurización.
Color Screen Control

1. Muestra todos los tipos de temperaturas de control del proceso.
2. Muestra el nivel de líquido del medio conductor del calor en el vaso de expansión.
3. Indicación de funcionamiento del sistema de refrigeración.
4. Muestra la indicación de funcionamiento del calentador.
5. Muestra la indicación de funcionamiento de la bomba de circulación.
6. Muestra el control de temp. ( patrón de control de temp. de materiales, control de temp. media conductora de calor ).
7. Se puede ajustar el control del límite superior e inferior de la temperatura.
8. Se puede ajustar la diferencia de temperatura entre la camisa y el material del reactor.
9. Muestra la alarma para añadir el líquido cuando está vacío.
10. El compresor frigorífico puede funcionar de forma manual o automática.
Customized solutions to meet your temperature process needs
CUSTOM CHILLER SIZES
Whether it is portable, compact, large and small chillers, we can custom design them according to your requirements. No matter how many tons of chiller you need, we can create the best solution.
CUSTOM CHILLER TYPES
We provide chillers of various refrigeration types, including but not limited to air-cooled, water-cooled and evaporative-condensing chillers. Regardless of the type of refrigeration compressor, we can design it according to your requirements.
CUSTOM TEMPERATURE RANGES
We can create a custom solution for temperatures from -150℃ to +350℃. Custom temperature ranges for specific industries.
CUSTOM CHILLER VOLTAGE
Customize chiller voltage and phase according to your needs. Optional 110V/60HZ, 220V/60HZ, 380V/50HZ, 220V/50HZ, 400V/50HZ, 460V/60HZ, 440V~480V/60HZ, etc.
¿Por qué elegir lneya como proveedor de control de temperatura?
Años de experiencia
Clientes satisfechos
m² Área de producción
Tecnologías patentadas
Visite la fábrica de LNEYA
Contacto
Envíenos su solicitud y nos pondremos en contacto con usted en 24 horas