Buscar en toda la estación


News

Noticias sobre exposiciones

13p semi-closed air-cooled compression condensi...

13p semi-closed air-cooled compression condensing unit failure warning instructions

The 13p semi-closed air-cooled compression condensing unit is used in industrial cold processing. After using it for a long time, some problems will arise, Wuxi Guanya (LNEYA) reminds. There is usually a high-pressure alarm on the 13p semi-closed air-cooled compression condensing unit, which is automatically activated in the event of an accident. When we start, we will find that there is a fault indicator that is turned off. Because there is a fault now, it lights up. Some smart technologies ...

Ver detalles
How to solve the fault of the ultra-low tempera...

How to solve the fault of the ultra-low temperature refrigerator pressure controller?

If the industrial ultra-low temperature refrigerator encounters a controller-related failure during operation, if it is not resolved in time, the pressure controller may be unavailable. The pressure controller plays a very important role in the ultra-low temperature refrigerator group. Because of the pressure exerted between each accessory under the high-efficiency working state, the range is different. In order to reduce the impact of pressure on the ultra-low temperature refrigerator group,...

Ver detalles
How to clean LNEYA low temperature refrigerator?

How to clean LNEYA low temperature refrigerator?

LNEYA low temperature refrigerators need to be cleaned after a long time of use. So, how should the cleaning be carried out? How to clean it is not wrong? The low-temperature refrigerator cleaning includes the cleaning of the cooling water system and the cleaning of the chilled water system. The cleaning of the cooling water system is mainly to remove scales such as scale, biological slime and corrosion products from the inner wall of the pipeline and the heat exchange surface of the condense...

Ver detalles
Fabricantes de frigoríficos de baja temperatura&#821...

Instrucciones de ajuste energético de los fabricantes de frigoríficos de baja temperatura

The energy regulation of low-temperature refrigerator manufacturers' equipment during operation is also very important. In order to adapt to the change of energy load, Wuxi Guanya (LNEYA) low-temperature refrigerator manufacturers should pay attention to the energy regulation process. In order to adapt to the load change of the refrigeration system during the operation of the low-temperature refrigerator manufacturer, the water temperature of the unit still needs to maintain its constant requ...

Ver detalles
How to deal with frosting in cryogenic refriger...

How to deal with frosting in cryogenic refrigeration systems?

If the low temperature refrigeration system has been frosted, believing that some enterprises have met, then how should we deal with such situation? Are there any methods can solve this problem. Today, let's know something about it with LNEYA refrigeration company. 1. First turn off the suction valve of the low temperature box compressor and unload to the minimum number of cylinders to operate. 2. Then close the liquid supply valve of the intermediate cooler and close the suction valve of the...

Ver detalles
The maintenance and maintenance of an ultra-low...

The maintenance and maintenance of an ultra-low temperature refrigerator

The maintenance and maintenance of an ultra-low temperature refrigerator are very important for normal usage and prolonging its life. If the inaccurate temperature control often results in the damage of the protected objects, which will greatly affect the experimental results, thus affecting the normal progress of the research work.1. Clean it once a month to ensure its cleanlinessRemove the dust on the inside and outside of the refrigerator and accessories by a dry cloth. If the refrigerator...

Ver detalles
Process description of LNEYA screw chiller

Process description of LNEYA screw chiller

LNEYA screw chiller is suitable for all kinds of chemical, pharmaceutical, mechanical and other fields of production process cold source, can provide -25 ° C ~ 30 ° C chilled water, can be used as ice cold storage, low temperature air supply and other production processes required process cold source. LNEYA's screw chiller production specifications:1. Standard design conditions are: chilled water: effluent temperature 7 ° C, return water temperature 12 ° C; condensing temperature 30 ° C2. R...

Ver detalles
Impact and Solution of Excess Exhaust Temperatu...

Impacto y solución del exceso de temperatura de los gases de escape de las enfriadoras industriales

Industrial water chiller compressor exhaust temperature determines whether the equipment can stably and efficiently run. The common problem of compressor is excess exhaust temperature. Once the situation appears, it is easy to make industrial chiller high pressure and high temperature, overload, reduced working efficiency and poor industrial water chiller compressor refrigerating capacity. It can also lead to other problems. So how to reduce the exhaust temperature of industrial water chiller...

Ver detalles
Refrigeration principle of LNEYA glycol chiller...

Refrigeration principle of LNEYA glycol chiller system

Glycol Chiller System SUNDI -10℃ ~ 200℃, as we can tell from its name, it is to use Glycol as the refrigeration agent for the chiller.In the all air environment, because of the low temperature in the outdoors, it is impossible to use a cooling tower to supply the inner area directly with the cold air-conditioner. In addition, the cold air in the outdoors could be used directly as refrigerator source,with glycol as refrigerant, it can introduce the natural cold air into the inner area and su...

Ver detalles
Análisis de los motivos por los que no se...

Análisis de los motivos de la no refrigeración de los equipos de refrigeración criogénica

Ultra-low temperature refrigeration equipment is mainly used in industrial cold processing. Unlike some manufacturers of ultra-low temperature refrigeration equipment, LNEYA ultra-low temperature refrigeration equipment uses environmentally friendly refrigerant, which is conducive to the operation of ultra-low temperature refrigeration equipment. If the ultra-low temperature refrigeration equipment does not cool, how to Solve it? Generally speaking, if the ultra-low temperature freezer is not...

Ver detalles

Noticias del sector

¡Amplíe más!