Low temperature industrial freezer fan coil wiring instructions
The electric two-way valve red line of the low-temperature industrial freezer is 220V hot wire (L) directly connected to the thermostat fire line interface, the blue line is zero line (N), the coil, the two-way valve, the thermostat is connected in series, green, brown, Yellow, corresponding to the thermostat connected to the fan coil high, medium and low gear, the black line is the two-way valve fire line to the thermostat “open” interface, the control line is 6 color 1.0 square national standard line.
It should be noted that the two-way valve is normally closed, the power is automatically turned off, the electric water circuit is turned on, and the air conditioner starts to cool; therefore, in the wiring process of the two-way valve, it is found that the terminal of the thermostat is “off”. No wiring is required. The low-temperature industrial refrigerator drive head is burned, and the general two-way valve will be automatically closed. The emergency measures can be forced to open the two-way valve through the small handle on the drive head to ensure the air cooling and heating.
When the low-temperature industrial refrigerator electric ball valve is wired, the red line is 220V fire line (L) directly connected to the thermostat fire line interface, the blue line is zero line (N), the coil, the two-way valve, the thermostat is connected in series, green, brown, Yellow, corresponding to the thermostat connected to the fan coil high, medium and low gear, black line for the two-way valve fire line to the thermostat “open” interface; Yan Hong line for the two-way valve to the thermostat “off” interface The control line is a national standard line of 7 colors and 1.0 square. It should be noted that this type of electric ball valve only needs to be energized once when the water circuit is turned on and off. When the action is completed, the power is automatically turned off. Unlike the above-mentioned low-temperature industrial refrigerator two-way valve, it is not necessary to energize the switch for a long time. Remove it and use a manual wrench to force the valve body to open or close.
The wiring of the electric two-way valve is not connected to the red wire 220V live wire (L) directly connected to the thermostat fire line interface, the blue line is zero line (N), the coil and the thermostat are connected in series, green, brown, yellow, respectively The thermostat is connected to the high, medium and low gears of the fan coil. The control line is a 5-color 1.0 square national standard line. The low temperature industrial freezer can only adjust the coil wind speed, and the temperature cannot control the opening and closing of the chilled water.
Different low temperature industrial refrigerators are somewhat different in these aspects, so we need to distinguish them one by one.
Recomendaciones relacionadas
-
The ethylene glycol chiller solution is too cold and too hot
1706When the ethylene glycol chiller solutionis overheated and overcooled during operation, if you don't understand theseconditions well, you will not be able to operate the equipment well.The supercooling phenomenon of the solutionof the glycol ch...
Ver detalles -
Cooling water circulator for BMS testing of liquid-cooled battery packs
1578As the weather temperature gradually increases, the use of liquid-cooled battery pack BMS test cooling water circulators also gradually reaches its peak. Liquid-cooled battery pack BMS test cooling water circulators have rated power ranging from s...
Ver detalles -
Precautions for use of minus 95 degrees cryogenic liquid bath cold trap
1728The minus 95 degree low temperature liquid bath cold trap (that is, the refrigerator that we often say) is a common refrigeration unit in refrigeration equipment. The rational use of the unit can not only avoid the failure of the unit, but also ma...
Ver detalles -
Prueba del motor del vehículo eléctrico Instrucciones del enfriador del sistema de refrigeración
2081Con el continuo desarrollo de los vehículos de nueva energía, también se está desarrollando el enfriador, el sistema de refrigeración para pruebas de motores eléctricos. El nuevo enfriador para pruebas de motores de vehículos de nueva energía puede ajustar de forma adaptativa el enfriador en función de la dinámica...
Ver detalles
LNEYA Enfriadoras industriales Fabricante Proveedor