The principle of LNEYA chiller
Industrial chillers are commonly used to cool products and machinery for a variety of different applications, including injection molding, tools and die cutting, food and beverage, chemicals, lasers, machine tools, semiconductors and more.
In most process cooling applications, the pumping system circulates cold water or water/glycol solution from the chiller to the process. This cooled fluid removes heat from the process and the warm fluid returns to the cooler. Process water is a means of transferring heat from the process to the cooler.
The process cooler contains a compound called a refrigerant. There are many types of refrigerants and applications depending on the temperature required, but they are all based on the fundamental principle of compression and phase change of the refrigerant from liquid to gas and back to liquid. This process of heating and cooling the refrigerant and changing it from a gas to a liquid and returning again is a refrigeration cycle.
The refrigeration cycle begins with a low pressure liquid/gas mixture entering the evaporator. In the evaporator, heat from the process water or water/glycol solution causes the refrigerant to boil and the refrigerant to change from a low pressure liquid to a low pressure gas. The low pressure gas enters the compressor where it is compressed into a high pressure gas. The high pressure gas enters the condenser, and the ambient air or condenser water removes heat and cools it into a high pressure liquid. The high pressure liquid moves to the expansion valve, controlling the amount of liquid refrigerant entering the evaporator, including restarting the refrigeration cycle.
LNEYA air-cooled cooling equipment uses ambient air to cool and condense hot refrigerant gas back into the liquid. It can be located inside the cooler or can be remotely located outside, but in the end it will block the heat from the cooler to the air. In a water-cooled condenser, water from the cooling tower cools and condenses the refrigerant.
Recomendaciones relacionadas
-
Treatment of organic waste gas by condensation method
1965Condensation treatment of organic waste gas equipment should pay attention to its performance when selecting. It is very necessary to choose high-performance condensation method to treat organic waste gas. So what is the use of organic waste gas f...
Ver detalles -
Linear rapid temperature change tester emptying and filling instructions
1792Before starting the linear rapid temperature change tester, check whether the relevant protective measures are in place, such as fire protection, protection, leak prevention and other tools. Check whether the power supply is in place according to ...
Ver detalles -
Aplicación del compresor en refrigeradores de baja temperatura
1587Compressor is an important part of cryogenic refrigeration industry. As far as low temperature chiller is concerned, different brands and types need to be selected when buying compressors. Therefore, when choosing cryogenic refrigeration compresso...
Ver detalles -
¿Cómo elegir el precio del sistema semiconductor de temperatura constante?
1772Now, it can be said that most of the industrial productions require semiconductor constant temperature systems to provide professional refrigeration. An efficient semiconductor constant temperature system can provide great help for various industr...
Ver detalles
LNEYA Enfriadoras industriales Fabricante Proveedor