Buscar en toda la estación


Centro de noticias

Sistema de forzado por temperatura/ Máquina de ensayo de impacto por chorro

AET -75℃~250℃

Air Cooling Chiller For chuck/chamber/Heat plate
  • Precisión del control de temperatura±0.5℃
  • Air treatment22m³/h~95m³/h
  • Tipo de refrigeraciónwater cooling/air cooling

Modelo AET-4025 AET-4050 AET-4095W AET-7025 AET-7050W AET-7095W
AET-4025C AET-4050C AET-4095WC AET-7025C AET-7050WC AET-7095WC
Temperatura  -40℃~250℃  -75℃~250℃
Precisión del control de temperatura Gas outlet temperature control ±0.1°C, long-distance process temperature control accuracy ±0.5°C. You can choose to control the outlet gas temperature and process target temperature
Upgrade temperature rate The temperature rise and fall rate of the gas temperature at the equipment outlet is greater than 30°C/min, and gradient temperature rise and fall can be performed
Air requirements Air filter <5um Air oil content <0.1um Air temperature and humidity: 5°C-32℃℃ 0-50%RH Pressure 4bar~8bar
Air treatment 22m³/h 50 m³/h 95m³/h 22m³/h 50 m³/h 95m³/h
Método de estrangulamiento The refrigeration system uses electronic expansion valve throttling to accurately control the cooling capacity
Controlador PLC programmable controller, standard support Modbus RTU protocol, RS485 interface, other communication protocols can be selected
Display record 7-inch color touch screen, can display gas temperature, pressure, flow, refrigeration system pressure and temperature
Process temperature control Self-created model-free self-building tree algorithm combined with general anti-lag cascade algorithm to control process temperature
Dimensiones cm 43*46*112 52*57*132 60*63*160 54*69*112 65*85*132 75*95*160
Remarks Suffix W represents water cooling and suffix c represents gas recycling

Send us a message about AET series
*
*
正在提交中....
提交成功!
提交失败!请稍后再试
邮箱错误!
电话错误!

Productos recomendados

  • FLTZ Double Frequency Conversion Series"      /&gt;<figcaption><span>Model FLTZ-305W FLTZ-305W/2T Double System Temp Range -30℃~40℃ -30℃~40℃ -30℃~40℃ Temp control accuracy ±0.1℃ ±0.1℃ ±0.1℃ Flow Control 15~45L/min ±0.3 15~45L/min ±0.3 15~45L/min ±0.3 Pump Pressure 6bar m…</span></figcaption></figure></a></div><div class=FLTZ Double Frequency Conversion Series

    Model FLTZ-305W FLTZ-305W/2T Double System Temp Range -30℃~40℃ -30℃~40℃ -30℃~40℃ Temp control accuracy ±0.1℃ ±0.1℃ ±0.1℃ Flow Control 15~45L/min ±0.3 15~45L/min ±0.3 15~45L/min ±0.3 Pump Pressure 6bar m…

  • Serie multicanal FLTZ"      /&gt;<figcaption><span>Heating method within 40 ℃ adopts a compressor hot gas heating fully enclosed design, and the machine operates continuously for 24 hours Mainly used for precise temperature control in semiconductor prod…</span></figcaption></figure></a></div><div class=Serie multicanal FLTZ

    Heating method within 40 ℃ adopts a compressor hot gas heating fully enclosed design, and the machine operates continuously for 24 hours Mainly used for precise temperature control in semiconductor prod…

  • Enfriadora de intercambio térmico ETCU"      /&gt;<figcaption><span>Temp Range:+5℃~90℃ ±0.3℃ Cooling Capacity: 5kw~30kw Tank volume: 6L~15L Power: 06KW~1.6KW Heating method within 40 ℃ adopts a compressor hot gas heating fully enclosed design, and the machine operates…</span></figcaption></figure></a></div><div class=Enfriadora de intercambio térmico ETCU

    Temp Range:+5℃~90℃ ±0.3℃ Cooling Capacity: 5kw~30kw Tank volume: 6L~15L Power: 06KW~1.6KW Heating method within 40 ℃ adopts a compressor hot gas heating fully enclosed design, and the machine operates…

cargando...

已经是到最后一篇内容了!