Buscar en toda la estación

AES Series Thermal Stream Temperature Forcing System

AES Series Thermal Stream Temperature Forcing System

APLICACIONES

AES series for Automatic test equipment in semiconductor, aerospace, military and other industries.

Such as ATE is used to measure the output signal of semiconductor devices,Used to evaluate the properties and performance of DUT, UUT, EUT to ensure use.

 

The output airflow cover of the testing machine will be covered bythe test product to form a test chamber with a relatively closedspace. The high or low temp airflow output by the testing machinewill cause the surface temp of the test product to change drastically,thus completing the corresponding high and low temp impact test.

It can isolate one lC or original component among many componentsand separately perform high and low tempimpact withoutaffecting other surrounding devices. Compared with the traditionalthermal shock test box, the temp impact rate is faster.

Compared to the traditional thermostat, there are several features:
Temperature range: -120 °C ~ +300 °C;
The temperature rise and fall is very fast, -55 °C ~ 150 °C < 10 seconds;
Temperature control accuracy: ±1 °C;
Temperature setting capability: ±0.1 °C;
Temperature display capability: ±0.1 °C;
Maximum air flow: 25m3/h;
Real-time monitoring of the real temperature of the IC under test to achieve closed-loop feedback and adjust the gas temperature in real time;
The temperature rise and fall time is controllable, programmable operation, manual operation and remote control.

 

Temperatura -40℃~225℃ -60℃~225℃ -80℃~225℃ -100℃~225℃ -120℃~225℃
Precisión de la temperatura ±0.1℃(Steady state outlet temperature)
Air requirements Air filter < 5um air oil content < 0.1um air temp and humidity:5℃-32℃ 0-50%RH
Air treatment capacity 10m³/h-m³/h  pressure 5bar-7.6bar
Método de estrangulamiento Válvula de expansión electrónica
Controlador PLC Controller
Visualizar y grabar The pressure of the refrigeration system is realized by a pointer pressure gauge, and the pressure
of the circulation system is detected by a pressure sensor and displayed on the touch screen.
Componentes principales Danfoss drying filter, Casto solenoid valve, Danfoss pressure controller, EBM fan ( air-cooled ), Danfoss
/ Emerson oil separator, SMC filter, Emerson electronic expansion valve, Johnson pressure sensor
Compresor Tecumseh,Dorin
High temp cooling Possess high-temperature 225℃ direct cooling technology to meet the target and quickly cool
down during high-temperature operation.
Process control The remote target temperature can be controlled by combining the self created model free self built
tree algorithm and cascade algorithm
Talla 540*690*1320 540*690*1320 540*690*1320 800*1200*1750 1000*1500*1850

 

APLICACIONES

Más información

Semiconductor packaging and testing temp control solution


Desde nuestra fundación en 2006hemos atendido a más de 30.000 clientes y poseemos varias patentes que demuestran nuestra innovación y fiabilidad. Nuestros enfriadores son seleccionados por más de 100 universidad proyectos de laboratorio en todo el mundo y exportados a más de 20 países. Garantizamos la máxima calidad mediante un riguroso 3 pasos proceso de control de calidad: inspección visual, pruebas de rendimiento y pruebas de seguridad eléctrica. Nuestro compromiso con la excelencia está respaldado además por nuestro Atención al cliente 24/7 compromiso de asistencia. Además, contamos con agentes en Estados Unidos, Canadá, Australia, Rusia y Corea del Sur, lo que nos convierte en un socio global de confianza para sus necesidades de enfriadoras. Elija lneya por calidad y asistencia para su proyecto.
18+

Años de experiencia

30000+

Clientes satisfechos

25000

m² Área de producción

80+

Tecnologías patentadas

*
*
Envío....