Introducción del principio de destilación y del dispositivo de control del ciclo de temperatura
La destilación es un método común para purificar sustancias líquidas y separar mezclas. El punto de ebullición del compuesto también puede medirse por destilación, por lo que también tiene cierta importancia para la identificación de co...
The change of saturated vapor pressure of a substance at different temperatures is the basis of distillation separation. Heating the liquid to boiling makes the liquid into a vapor, and then the vapor is cooled and then condensed into a liquid. The combined operation of these two processes is called distillation.
The boiling points of the components of the liquid mixture must be very different, at least above 30 ° C to achieve a better separation effect. Select the heating device according to the boiling point of the distilled liquid. When the boiling point of the distilled liquid is below 80oC, use a hot water bath to heat; when the boiling point of the liquid is above 100 ° C, use a simple air bath or an oil bath to heat the asbestos mesh When the temperature is above 200 ° C, use a sand bath, an air bath and an electric heating mantle.
In the distillation operation, the following points should be noted:
(1) Control the heating temperature. If a heating bath is used, the temperature of the heating bath should be several degrees higher than the boiling point of the distilled liquid, otherwise it will be difficult to distill the distillate. The more the heating bath temperature is higher than the boiling point of the distilled liquid, the faster the distillation speed. However, the temperature of the heating bath should not be too high, otherwise it will cause the vapor pressure of the distillation flask and the upper part of the condenser to exceed atmospheric pressure, which may cause accidents, especially when distilling low-boiling substances.
The temperature should be strictly controlled during distillation because things that are too low can not be steamed out, and those that are too high can be steamed out, and may also cause the decomposition of the required substances, or the decomposition of undesired substances to generate new impurities! Prolonging the time can make the distillation process more adequate.
LNEYA sistema dinámico de control de la temperatura SUNDI series temperature range is -120 ℃ to 350 ℃, superior performance, high precision, intelligent temperature control. Fully enclosed system, extending the thermal conductivity of the liquid, a very wide temperature range, without changing the liquid medium. The ultra-high temperature cooling technology can directly cool from the high temperature of 300 degrees. The temperature difference between the jacket oil and the raw material process can be set separately to control the process temperature and jacket temperature separately.
|
Recomendaciones relacionadas
-
Working characteristics of industrial high temperature and low temperature cooling system
1511The industrial high-temperature and low-temperature cooling system is mainly used for the monitoring and control of temperature, pressure, flow, liquid level, humidity, pH value and other parameters. It has the characteristics of high control acc...
Ver detalles -
Analysis of Advantages and Disadvantages of Screw Water Chiller
2017Compared with other types of chillers, the overall energy consumption of high-quality screw water chiller is relatively small. Because the production technology of screw water chiller is more advanced and less energy is used, the equipment can qui...
Ver detalles -
¿Cómo elegir un reactor de vidrio? Cómo ajustar el sistema de control de temperatura?
1566Glass kettle reactors are required for many laboratory equipment and are generally used with temperature control systems. In the chemical and pharmaceutical fields, the imported glass reactor is basically a necessity, and the refrigeration heatin...
Ver detalles -
Ventajas del refrigerador de recirculación de baja temperatura
1406El enfriador de recirculación de refrigeración de baja temperatura es un tipo de refrigeración que utiliza compresor, y la bomba de circulación proporciona la fuente de frío para mantener el rango de temperatura de - 2 5 ℃ a 30 ℃. El enfriador de recirculación de refrigeración tiene un ahorro de espacio ...
Ver detalles
LNEYA Enfriadoras industriales Fabricante Proveedor










