El pequeño compresor de la cámara de pruebas ambientales debe prestar atención después del mantenimiento
En la cámara centrífuga de pruebas ambientales a pequeña escala, el dispositivo de recuperación de la succión es generalmente un sistema independiente y, si es necesario, la tubería conectada al condensador y al evaporador puede cerrarse para su mantenimiento por separado. Después de r...
After replacing the compressor in the small environmental test chamber, the pumping recovery device generally uses the automatic mode to open, stop and work during the operation of the unit. Therefore, the oil level of the oil separator of the piston compressor should be strictly monitored. Strictly monitor the level of the refrigerant in the recovery condenser. If the liquid level is not visible, the recovery condenser is not effective. Check whether the coolant line and the filter are blocked. If the non-condensable gas removed by the bleed valve contains more refrigerant gas, check if the float valve at the top of the recovery condenser is stuck.
If the venting valve that is automatically vented in the small environmental test chamber does not open the deflation when the specified pressure value is reached, the operation of the suction recovery device should be stopped and the exhaust valve should be overhauled. Frequent activation of the pumping recovery unit indicates that a large amount of air has leaked into the unit. Before the start of the refrigeration unit or during the start-up process, the manual operation of the suction recovery device is generally adopted. The time of each operation is limited by the decrease of the condensing pressure and the heat of the piston compressor motor casing. Generally, the continuous operation time is less than 30 minutes. If the small environmental test chamber is not used for a long time, it can be turned on for a short time to lubricate the compressor part. If the small environmental test chamber does not need to exclude non-condensable gases, the unit should also be operated for 15 to 20 minutes per day or several days.
The maintenance of the small environmental test box is also inevitable. It is recommended to make regular maintenance plans and carry out maintenance in a timely and effective manner.
Recomendaciones relacionadas
-
Precautions for non-use of reactor water-cooled chiller shutdown
1642When the reactor water-cooled chiller hascomplete accessories, in actual use, it is necessary to provide it with regularrest time. In order to maintain stable performance of the chiller duringlong-term operation, users need to master the method...
Ver detalles -
instrucciones de selección del refrigerador del reactor de 500 litros
1633El enfriador de reactor de 500 litros se utiliza más en la industria farmacéutica. Por lo tanto, el usuario necesita seleccionar un fabricante regular al seleccionar, y al mismo tiempo, entender las características y configuración. Para la selección del enfriador de 500 litros r...
Ver detalles -
Practical application area of air-cooled chiller
1515Air cooled chillers, as the name implies,are mainly used in colleges and universities, scientific research andlaboratories. Specially for the cooling of small laboratory equipment such asspectrometer, mass spectrometer, viscometer, rotation, fe...
Ver detalles -
Working Principle and Process of Chiller Temperature Control and Pressure Controller
2610Air cooled chiller temperature controller is a two - position regulator, also known as chiller temperature control relay.According to the change of adjusted temperature,the chiller temperature control makes the contact on or off, thus controlling ...
Ver detalles
LNEYA Enfriadoras industriales Fabricante Proveedor