Precautions for installing reactor refrigeration and heating circulator
The reactor refrigeration and heating cycle equipment can achieve high temperature of 200℃ and low temperature constant temperature test of -120℃, providing users with a field source with controlled thermal cooling and constant temperature. It can also be used as a heat source or cold source for direct heating, cooling, auxiliary heating, and auxiliary refrigeration. Source, temperature control within the full range, used in diffusion process control of semiconductor diffusion furnaces, constant temperature control or external circulation applications in reactors, fully automatic synthesis instruments, extraction and condensation devices.
Working principle of reactor refrigeration and heating cycle equipment:
The reactor refrigeration and heating cycle equipment uses coolant as the heat transfer medium to transport the heat generated by other instruments or equipment that need to be cooled, and sends the heat to the outside of the equipment through the refrigeration system to ensure that the equipment works within the normal temperature range. The device and the instrument rely on the pressure of the pump in the device to form a closed medium circulation, and the temperature sensor is used to detect the temperature of the medium to realize the control of the cooler.
Installation environment of reactor refrigeration and heating cycle equipment:
The reactor refrigeration and heating cycle equipment has a semi-closed cycle. At high temperatures, no oil mist evaporates, and the thermal oil will not be oxidized and browned. At low temperatures, it will not absorb water vapor in the air, extending the life of the thermal oil. Reactor refrigeration and heating cycle equipment should be installed in a laboratory with a good environment; it should be installed on a well-ventilated, dust-free, stable floor or experimental table to avoid droplets, excess vapor, and possible inflow, stagnation, and leakage of flammable gases. Avoid places that can generate high-frequency equipment (high-frequency welding machines, etc.).
When the reactor refrigeration and heating cycle equipment avoids frequent use of acidic solutions and frequent use of special sprayers (containing sulfides, etc.), from the perspective of convenience and safety during maintenance and installation, try to ensure that there is a gap between the indoor unit and obstacles. have enough space.
Follow the instructions when installing:
The use of 300°C refrigeration and heating cycle equipment is inseparable from its standardized operation. When selling, there will be corresponding instructions for use when the equipment leaves the factory. Users can understand it in advance when using it.
The reactor refrigeration and heating cycle equipment is simple to install and operate, and does not require professional operation. The operator can be operated with simple training or by following the instructions; the heating method is circulating heating, so there is no loss of the medium; no need Annual review.
Summarize
The reactor refrigeration and heating cycle equipment is heated evenly, and the temperature adjustment adopts PID self-tuning intelligent control. The temperature control accuracy is ±1°C, which can meet the strict requirements of high process standards. Closed cycle heating, small heat loss, wide range of use.
Serie de conversión de frecuencia SUNDI Z
WHATSAPP WECHAT La tecnología de refrigeración de ultra alta temperatura puede enfriar directamente desde una alta temperatura de 300℃[porque sólo el medio de transferencia de calor en la expansión...
SUNDI -10℃~150℃
Sistema completamente cerrado, un solo medio completa la refrigeración y la calefacción -120~350℃ ±0.5℃ AC 380V 50HZ 8kW max Tecnología de enfriamiento de ultra alta temperatura puede enfriar directamente de...
SUNDI -80℃~250℃
● Temperaturas de trabajo de -120°C a +350°C ● Rendimiento hasta ahora inalcanzable ● Control inteligente de la temperatura ● Máxima estabilidad y reproducibilidad del proceso ● Intercambiador de calor de placas Adop, calentamiento por tuberías, el he...
SUNDI-320/320W
Sistema completamente cerrado, un solo medio completa la refrigeración y la calefacción -120~350℃ ±0.5℃ Tecnología de enfriamiento de temperatura ultra alta Puede enfriar directamente desde 300℃ de alta temperatura. Por...
SUNDI -25℃~200℃
Sistema totalmente cerrado, un solo medio completa la refrigeración y la calefacción -120~350℃ ±0,5℃ ● Temperaturas de trabajo de -120°C a +350°C ● Rendimiento hasta ahora inalcanzable ●Control inteligente de la temperatura....
SUNDI -25℃~300℃
● Temperaturas de trabajo de -120°C a +350°C ● Rendimiento hasta ahora inalcanzable ● Control inteligente de la temperatura ● Máxima estabilidad y reproducibilidad del proceso ● Intercambiador de calor de placas Adop, calentamiento por tuberías, el he...
SUNDI -45℃~250℃
● Temperaturas de trabajo de -120°C a +350°C ● Rendimiento hasta ahora inalcanzable ● Control inteligente de la temperatura ● Máxima estabilidad y reproducibilidad del proceso ● Intercambiador de calor de placas Adop, calentamiento por tuberías, el he...
SUNDI -60℃~250℃
La tecnología de refrigeración de ultra alta temperatura puede enfriar directamente desde una alta temperatura de 300℃[porque sólo el medio de transferencia de calor en la cámara de expansión entra en contacto con ox...
cargando...
已经是到最后一篇内容了!
VIDEO
Recomendaciones relacionadas
-
HRT -45℃~250℃
2202The cooler is a very important part of the screw air compressor. The main function is to cool the lubricating oil of air compressor and the compressed air. If it's blocked, then the temperature will go up. A main cause of t...
Ver detalles -
KRY 0℃~+100℃(1&6)
2174Temperature simulation for vehicle quality test: battery life test, fuel injector/motor test bench, airbag test, component test bench, etc. It can simulate the external environmental conditions in the climat...
Ver detalles -
SUNDI -45℃~300℃
1454● Temperaturas de trabajo de -120°C a +350°C ● Rendimiento hasta ahora inalcanzable ● Control inteligente de la temperatura ● Máxima estabilidad y reproducibilidad del proceso ● Intercambiador de calor de placas Adop, calentamiento por tuberías, el he...
Ver detalles -
SUNDI -100℃~100℃
2062● Temperaturas de trabajo de -120°C a +350°C ● Rendimiento hasta ahora inalcanzable ● Control inteligente de la temperatura ● Máxima estabilidad y reproducibilidad del proceso ● Intercambiador de calor de placas Adop, calentamiento por tuberías, el he...
Ver detalles