What Is the Range of Industrial Chiller Temperature Control
Industrial chiller is a common refrigeration equipment in industrial refrigeration industry,whose feature is various types, complete models and wide range of applications.More importantly, the precision of chiller temperature control is high and the ranger of it is wide.So,what is the range of industrial chiller temperature control and how to set it?
High temperature industrial chiller (5 ~ 30.0 ℃)
This kind of chiller can control the temperature between 5-30 ℃,using conventional refrigerants.In other words, when the chiller temperature control range is being adjusting,the set of the lowest temperature of the industrial chiller is 5℃ and the highest is 30℃.It is the most widely used temperature control range in the industry.
Medium temperature type industrial chiller (0 ~ 15.0 ℃)
Water freezes at 0 ℃.It is a common sense that old people and children can know.So,if industrial chiller is required to provide subzero cryogenic coolant,will it be realized?The answer is yes.The temperature of medium temperature industrial chiller can be set between 0 ℃ ~ 15 ℃.The refrigerant can be calcium chloride (saline) or ethylene glycol aqueous solution.
Low temperature industrial chiller
Low temperature industrial chiller which can provide (low temperature freezing liquid below -15℃~-35℃) is usually used in chemical industry and pharmaceutical industry for recycling material cooling or material in reaction kettle condensation.
Cryogenic type industrial chiller
Industrial cold chiller which can provide low temperature freezing liquid below 35 ℃, is called Cryogenic type industrial chiller.It adopts binary or ternary cascade refrigeration system, so it is also known as the cascade industrial chiller. Thus, the industrial chiller temperature control range is really wide.
Recomendaciones relacionadas
-
Inspección de mantenimiento de la unidad de refrigeración de baja temperatura
1755Low-temperature refrigeration units usually need to do a maintenance. After the maintenance is done, it is not easy to fail, and there will be more markets. If it is not easy to fail, it will not stop working, which is equivalent to saving the com...
Ver detalles -
Nota de parada de la condensación de purificación de gases residuales orgánicos
1893If the organic waste gas is purified and condensed, if it encounters a fault during operation, it should be shut down and disposed of in time. Then, how can LNEYA organic waste gas purification and condensation be used once it is shut down? The or...
Ver detalles -
¿Cuáles son los factores que influyen en el precio de los equipos de calefacción industrial en la industria?
1514El precio de los equipos de calefacción y termorregulación es un aspecto que preocupa a muchos clientes. El precio está relacionado con la marca, las materias primas y la tecnología. Al mismo tiempo, la configuración de los parámetros técnicos del producto también tiene un gr...
Ver detalles -
Application of refrigeration and heating temperature control system in chemical synthesis
1356chemical synthesis cooling heating system temperature control unit
Ver detalles
LNEYA Enfriadoras industriales Fabricante Proveedor