AES -115℃~225℃
Temperature Forcing System/ “Thermal Stream”- Time switching10s~20s
- RefrigeranteR404A/R23/R14/R508B
- Agua de refrigeración0.6m³/h~3m³/h
- Gama de potencia3,7 kW~7,5 kW
Descarga de datos del producto
Parámetros detallados
Modelo | AES-4535 | AES-6035 | AES-8035 | AES-A1035W | AES-A1235W | |
AES-4535W | AES-6035W | AES-8035W | ||||
Temp. Rango | -45℃~225℃ | -60℃~225℃ | -80℃~225℃ | -100℃~225℃ | -120℃~225℃ | |
Potencia calorífica | 3,5 kW | 3,5 kW | 3,5 kW | 4,5 kW | 4,5 kW | |
Temp. Control Accuracy | ±0.5℃ | ±0.5℃ | ±0.5℃ | ±0.5℃ | ±0.5℃ | |
Temp. Conversion Time | -25℃ to 150℃ Approximately 10S 150℃ to -25℃ Approximately 20s |
-45℃ to 150℃ Approximately 10S 150℃to -45℃ Approximately 20s |
-55℃ to 150℃ Approximately 10S 150℃to -55℃ Approximately 15s |
-70℃ to 150℃ Approximately 10S 150 ℃to -70℃ Approximately 20s |
-80℃ to 150℃ Approximately 11S 150℃to -80℃ Approximately 20s |
|
Air Requirement | Air Cleaner<5um | |||||
Air Oil Content:<0.1ppm | ||||||
Air Temp&Humidity:5℃~32℃ 0~50%RH | ||||||
Air Handing Capacity | 7m3/h ~ 25m3/h Pressure 5bar~7.6bar | |||||
System Pressure Dispiay | La presión del sistema de refrigeración se realiza mediante un manómetro (alta presión, baja presión); | |||||
La presión del sistema circulatorio se detecta mediante un sensor de presión y se muestra en la pantalla táctil. | ||||||
Controlador | Siemens PLC, Fuzzy PID Control algorithm. | |||||
Temp. Control | Control of outlet temperature | |||||
Programable | Se pueden desarrollar 5 procedimientos, y cada programa puede constar de 40 pasos | |||||
Protocolo de comunicación | Ethernet Interface TCP/IP Protocol. | |||||
Internal Temp. Feedback | Equipment outlet temperature, refrigeration system condensation temperature, ambient temperature, compressor suction temperature, cooling water temperature (water cooling equipment is configured) . | |||||
Temp. Feedback | T Temperature Sensor | |||||
Motor de compresión | Taikang,France | Taikang,France | Taikang,France | Italy Duling | Italy Duling | |
Evaporímetro | Double-pipe (heat) Exchanger | |||||
Calorifier | Flanged Barrel Heater | |||||
Accesorios de refrigeración | Danfoss / Emerson fittings (dry filters, oil separators, high and low pressure protectors, expansion valves, solenoid valves). | |||||
Panel de control | Pantalla táctil en color de 7 pulgadas personalizada LNEYA, visualización de la curva de temperatura, exportación de datos EXCEL | |||||
Vigilancia segura | Con función de autodiagnóstico; disyuntor de secuencia de fases, protección contra sobrecarga del congelador; presostato de alta tensión, relé de sobrecarga, dispositivo de protección térmica y otras funciones de protección de seguridad. | |||||
Criógeno | Topsubmixed Refrigerant | |||||
External Insulation Hose | 8m DN32 fast coupling clamp for easy outgoing insulation hose | |||||
Refrigerante | R404A | R404A/R23 | R404A/R508B | R404A/R23/R14 | R404A/R23/R14 | |
Shape Dimension (Wind)cm | 54*69*132 | 54*69*132 | 75*73*133 | 80*120*185 | 100*150*185 | |
Shape Size (Water)cm | 54*69*132 | 54*69*132 | 75*73*133 | 70*100*175 | 80*120*185 | |
Air-Cooled Type | Copper tube aluminum fin condensation mode, upper and out type, condensing fan using Germany EBM axial flow fan. | |||||
Water-Cooled Type W | El tipo W está refrigerado por agua | |||||
Water-Cooled Condenser | Sleeve type heat exchanger (Paris/ Shen’s) | |||||
Cooling Water Quantity At 25℃ | 0.6m3/h | 1.2m3/h | 1.6m3/h | 2,6 m3/h | 3m3/h | |
Fuente 380V 50HZ | 3.7kW max | 5 kW máx. | 5 kW máx. | 6.8kW max | 7,5 kW máx. | |
Fuente | Personalizable 460V 60HZN 220V 60HZ trifásico | |||||
Material de la carcasa | Cold rolled sheet spray (Standard Colour 7035). | |||||
Temp. Spread | High Temperature To +300℃ |
Descripción del producto
Provides accurate and fast ambient temperature (-120 °C ~ +300 °C) for chips, modules, integrated circuit boards, and electronic components. It is an indispensable instrument for product electrical performance testing, failure analysis, and reliability assessment.
Widely used in semiconductor companies, aerospace, optical communications, universities, research institutes and other fields.
Compared to the traditional thermostat, there are several features:
Temperature range: -120 °C ~ +300 °C;
The temperature rise and fall is very fast, -55 °C ~ 150 °C < 10 seconds;
Temperature control accuracy: ±1 °C;
Temperature setting capability: ±0.1 °C;
Temperature display capability: ±0.1 °C;
Maximum air flow: 25m3/h;
Real-time monitoring of the real temperature of the IC under test to achieve closed-loop feedback and adjust the gas temperature in real time;
The temperature rise and fall time is controllable, programmable operation, manual operation and remote control.
También pueden interesarle estos productos
cargando...
已经是到最后一篇内容了!